Downloader Programming; Testing The System - GE 60-806-95R-16Z - Security Concord Express System Control Panel Installation Instructions Manual

Installation instructions
Table of Contents

Advertisement

Chime On Close (25)
This setting determines whether or not a single
chime is sounded when a perimeter door or
window is closed.
System Version (30=factory code,
31=system number, 32=system level)
This menu lets you view and identify the panel
hardware and software version.
Note
A Downloader Phone Num-
ber must be programmed
and the user-programmable
option Downloading must be
set to on in order for remote
downloader programming to
work.
Testing the
System

Testing the System

¾
To turn Chime On Close off or on:
1. Enter user programming mode with the system master code. The display
shows
TIME AND DATE
2. Press A or B until the display shows
shows
DOWNLOADING OFF/ON
3. Press A or B until the display shows
ting).
4. Press 1 (off) or 2 (on). The display flashes the entered selection. Press ƒ
and the display shows the new setting.
System Version Menu
The
menu lets you view and identify panel hardware and software. This infor-
SYSTEM VERSION
mation is primarily used for troubleshooting purposes.
¾
To view and identify the System Version:
1. Enter user programming with the system master code. The display shows
USER CODES
2. Press A or B until the display shows
3. Press ƒ and the display shows
4. Press B and the display shows
5. Press B again and the display shows

Downloader Programming

The panel can be programmed remotely using ToolBox. Use the information you recorded in
Appendix A to inform the downloading operator of your installation programming requirements.
ToolBox Downloader Programming
¾
To initiate a ToolBox download session:
1. Contact your download station and ask the operator to prepare to download to the panel.
2. Make sure the system is disarmed.
+
3. Press 8
system master CODE
SYSTEM DOWNLOAD IN PROGRESS
If the alphanumeric touchpad does not display
loader operator to verify the downloader phone number and that ToolBox is set up properly.
Refer to the "Troubleshooting" section if the problem persists.
This section describes the following subjects:
Basic System Commands
Testing Zones/Sensors
Testing Phone Communication
Testing Central Station/Pager Communication
You should test the system after installing or servicing and after adding or removing devices from
the system. UL Listed systems should be tested weekly.
Refer to the "Troubleshooting" section if correct test results are not achieved.
.
OPTIONS
.
CHIME ON CLOSE OFF/ON
.
SYSTEM VERSION
FACTORY CODE nnn*nnnn
SYSTEM NUMBER *nnnnnnn
SYSTEM LEVEL nnnn
+
+
,
7
0 (any)
1 (down), or 2 (up). The display shows
during the downloading process.
SYSTEM DOWNLOAD IN PROGRESS
Options (Default=off)
, then press ƒ . The display
(current set-
(Default=N/A)
.
.
.
.
, call the down-
46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-80660-806-95rConcord express

Table of Contents