Cross-Zoning - GE 60-806-95R-16Z - Security Concord Express System Control Panel Installation Instructions Manual

Installation instructions
Table of Contents

Advertisement

No.
Name
Note: Check marks ( 3 ) represent characteristics present in a group.
* This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only .
† Sounds instant police siren if two or more sensors are tripped within 4 minutes. Otherwise sensors are followers to delayed
sensors. If Alarm Verification is on, group 18 functions like group 17.
‡ This group has not been investigated by UL.
§ This group is required for UL-listed residential fire alarm applications.
# See "Cross-Zoning" section on page 57
Note
Cross-Zoning is not recom-
mended for exit/entry zones.
Each zone has the ability to
individually protect the
intended area. (e.g. motion
detector patterns overlap).
Item # Sensor Text Item # Sensor Text Item #
001
Aborted
041
002
AC
042
003
Access
043
004
Active
044
005
Activity
045
006
Alarm
046
007
All
047
008
AM
048
009
Area
049
010
Arm
050
011
Armed
051
012
Arming
052
013
Attic
053
014
Auxiliary
054
015
Away
055
016
Baby
056
017
Back
057
018
Bar
058
57
Table A3: Sensor Group Characteristics (Continued)
Application

Cross-Zoning

Cross-Zone (Alarm Verify) refers to two different Group 10-20 sensors that must be tripped
within four minutes of each other to report an alarm to the central station. The diagram in
Figure 23 shows the path of a person walking from the kitchen to the living room. When the per-
son is detected walking through the kitchen, the motion sensor in the kitchen is tripped, sounding
a local alarm. If motion is detected by the living room motion sensor within two minutes, an
alarm report will be sent to the central station.
Figure 23. Cross-Zone Diagram
Table A4: Item Numbers and Sensor Text
Sensor
Text
Date
081
Gas
Daughter's
082
Glass
Degrees
083
Goodbye
Delay
084
Hallway
Den
085
Heat
Desk
086
Hello
Detector
087
Help
Dining
088
High
Disarmed
089
Home
Door
090
House
Down
091
In
Download
092
Install
Downstairs
093
Interior
Drawer
094
Intrusion
Driveway
095
Invalid
Duct
096
Is
Duress
097
Key
East
098
Kids
Alarm
Delay
Sensor
Item #
Item # Sensor Text Item #
Text
121
North
161
122
Not
162
123
Now
163
124
Number
164
125
Off
165
126
Office
166
127
OK
167
128
On
168
129
Open
169
130
Opening
170
131
Panic
171
132
Partition
172
133
Patio
173
134
Pet
174
135
Phone
175
136
Please
176
137
PM
177
138
Police
178
Appendix A: System Configuration Worksheets
Sensor Text
Siren
201
G
Sliding
202
H
Smoke
203
I
Son's
204
J
Sound
205
K
South
206
L
Special
207
M
Stairs
208
N
Stay
209
O
Supervisory 210
P
System
211
Q
Tamper
212
R
Temperature 213
S
Test
214
T
Time
215
U
To
216
V
Touchpad
217
W
Trouble
218
X
Active
Levels

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-80660-806-95rConcord express

Table of Contents