Dimm Temperature Warning In Vmware Esx 3.5 And Esx 4.0; Mfs5000Si Compute Module Occasionally Hangs During Lto-4 Tape Backup Operations; Virtual Drives Within A Storage Pool May Lose Server Assignments After A Virtual Drive Has Been Deleted - Intel MFSYS25V2 Specification

Modular server system / compute module specification update
Hide thumbs Also See for MFSYS25V2:
Table of Contents

Advertisement

Specification Update
35.

DIMM temperature warning in VMWare ESX 3.5 and ESX 4.0

Problem
VMWare ESX 3.5 and ESX 4.0 pick up a sensor as DIMM9 temperature and
report a DIMM temperature warning.
Implication
VMWare ESX 3.5 and ESX 4.0 generates a false DIMM temperature warning
for DIMM9.
Status
Fixed in UFU V4.0.
36.
MFS5000SI compute module occasionally hangs during LTO-4 tape
backup operations
Problem
MFS5000SI compute module occasionally hangs during LTO-4 tape backup
operations. The backup operation byte count will stop incrementing and access
to the server compute module will also slow down. Attempts to cancel the tape
backup job in progress or to restart Backup Exec services appear to hang as
well.
Implication
MFS5000SI compute modules occasionally hang during LTO-4 tape backup
operations.
Status
Fixed in UFU5.5.
37.
Virtual Drives within a Storage Pool may lose server assignments after a
Virtual Drive has been deleted
Problem
When a Virtual Drive within a Storage Pool is deleted, assignments for
subsequent Virtual Drives within the same Storage Pool may be lost during a
firmware update or after a power cycle of the SCM.
Implication
In the event that Virtual Drive assignments are lost, effected Virtual Drives must
be reassigned.
Status
Fix in future FW release.