Enterprise Platforms and Services Division
15.
Relative and Absolute KVM Mouse Mode not Supported on all Operating
Systems
Problem
Two mouse modes are available, Relative (the default) and Absolute – both are
not supported for all Operating Systems.
Implication
Absolute mouse mode is used with Microsoft® Windows and other operating
systems that compute mouse movements from absolute X, Y coordinates.
Relative mouse mode is used primarily with some Linux and Unix X/Windows
displays and other operating systems that compute mouse movements from
the change in relative position to the last position (how much the mouse
moved).
Workaround
When using Linux or other opertaing systems that compute mouse movements
from change in relative position you must change the mouse mode setting in
the KVM Viewer. Choose Mouse Mode from the KVM Viewer application
Options menu. Select Relative Mode. If the remote and local cursors are not
synchronized, toggle the Sync Cursor setting from On to Off and back to On.
Note:Mouse mode should be selected before starting CD Redirection. The
menu option will be disabled when CD redirection is enabled
Status
No Fix
16.
Compute Modules with RAID 6 Virtual Drives
Response
Problem
Compute Modules with a Raid 6 Virtual Drive from a Storage Pool with 9 or
more physical hard drives may experience slow response when transferring
very large files.
Implication
When the compute module storage configuration has a Raid 6 Virtual Drive
from a Storage Pool with 9 or more physical hard drives, the user may
experience an apparent system freeze when transfering very large files. When
monitoring CPU utilization using Task Manager while copying files, utilization
may drop to zero and the system will stop copying and responding to input.
The issue also does not occur in RAID 6 configurations from a Storage Pool
with less than nine hard disk drives or with Virtual Drives in RAID 5 or RAID 10
configurations.