Suse* Linux Enterprise Server 10 U1 Will Mark The Os Lun As Read Only If A Scm; Affinity Change Is Made While The Suse* Linux Enterprise Server 10 Operating System Is Running Or Booted; Chassis Fault Led Does Not Illuminate After Removing A Main Fan Module Or The I/O Fan Module - Intel MFSYS25V2 Specification

Modular server system / compute module specification update
Hide thumbs Also See for MFSYS25V2:
Table of Contents

Advertisement

Enterprise Platforms and Services Division
27.
SuSE* Linux Enterprise Server 10 U1 will mark the OS LUN as read only
if a SCM affinity change is made while the SUSE* Linux Enterprise Server
10 operating system is running or booted
Problem
SuSE* Linux Enterprise Server 10 U1 will mark the OS LUN as read only if a
SCM affinity change is made while the SuSE* Linux Enterprise Server 10
operating system is running or booted.
Implication
The OS LUN is marked as "read only".
Status
No Fix.
Workaround
Power down the SuSE* Linux Enterprise Server 10 U1 operating system. While
the operating system is powered down, go to the CMM UI and change the LUN
affinity.
28.
Chassis fault LED does not illuminate after removing a Main Fan module
or the I/O Fan module
Problem
When one or both of the Main Fan modules or the I/O Fan module is removed
from the system, the chassis fault LED does not illuminate.
Implication
There is no visual indication on the system that one or both of the Main Fan
modules or the I/O Fan module have been removed
Status
Fixed in UFU V5.5.