System Fault Led Does Not Turn On For All Critical Events; Email Alerting Not Enabled By Default For Three Critical Events - Intel MFSYS25V2 Specification

Modular server system / compute module specification update
Hide thumbs Also See for MFSYS25V2:
Table of Contents

Advertisement

Enterprise Platforms and Services Division
Workaround
None
Status
Fixed
11.

System Fault LED does not turn on for all critical events

Problem
System Fault LED will not turn on as expected when certain critical events
occur.
Implication
When the Processor Cache Size Mismatch error occurs, the system will boot
into BIOS setup; however, the System Fault LED will not turn on. Additionally
when the Correctable Memory Error Threshold is reached, the event will be
logged – however, the System Fault LED will not turn on.
Workaround
None
Status
Fixed
12.

Email Alerting not enabled by default for three Critical Events

Problem
On all critical event error logging, SNMP, and Email Alerting should be enabled
by default. However, three Critical Events do not by default have Email Alerting
enabled as expected.
Implication
Both SNMP and Email Alerting were not enabled by default in the event policy
for the following three events: Storage Subsystem – RAID Level Migration is
aborted due to an internal error, CMM m – System Component Unfit, and CMM
– CMM Internal Firmware Error.
Workaround
Administrator can go in and enable SNMP and Email Alerting for these three
events.