The Cmm Is Not Able To Provide Management Information For The Power Supply When An Axxpsu At Revision D73299-006 Is Installed In A System Chassis; The Network Time Server Setting On The Date/Time Web Page Of The Intel® Modular Server Control Gui Does Not Allow Selection Of Time Zones - Intel MFSYS25V2 Specification

Modular server system / compute module specification update
Hide thumbs Also See for MFSYS25V2:
Table of Contents

Advertisement

Specification Update
25.
The CMM is not able to provide management information for the power
supply when an AXXPSU at revision D73299-006 is installed in a system
chassis
Problem
The CMM is not able to provide management information, firware revision
number or manufacturing information for the power supply when an AXXPSU
at revision D73299-006 is installed in a system chassis.
Implication
In installations with firmware revision P2.3.5 the CMM will prompt "Install Power
Supplies" in the Action Required window; in installations with firmware revision
P2.6 that alert will not occur. In both cases, the PSU / system chassis will power
up. This erratum does not prevent powering up of the Server Compute Module.
Status
Fixed in UFU P2.6.
26.
The Network Time Server setting on the date/time web page of the
Intel® Modular Server Control GUI does not allow selection of time zones
Problem
The Network Time Server setting on the date/time web page of the Intel®
Modular Server Control GUI does not allow selection of different time zones.
Time Zone is set at GMT.
Implication
Network Time Server is always set to GMT.
Status
Fixed in V2.7
Workaround
None.