Specification Update
Workaround
Single wake-up packet can't completely wake-up the server, send more wake-
up packets can bring the server up.
Status
No Fix.
90.
CMM unable to send email alert if the sender address has a capital letter
in it
Problem
CMM with UFU v10.9 unable to send email alert if the sender address has a
capital letter in it.
Workaround
Don't use capital letter in email address.
Status
Fix in future UFU release.

Documentation Changes

1.
System Fault LED not depicted in front system views in Intel®
Modular Server System MFSYS25 documentation
Problem
System Fault LED is not identified in the front system view of the Intel®
Modular Server System MFSYS25 in the following documents: -008 MFSYS25
User Guide, -003 MFSYS25 Quick Start User's Guide, and -003 MFSYS25

TPS.

Clarification
The System Fault LED is located on the front of the chassis, in-between the I/O
Cooling Module and the server in the bottom slot of the chassis.
Status
Fixed