Error Message Codes - ADIC DAT 160 Installation And Operating Manual

Quantum dat 160: user guide
Table of Contents

Advertisement

Error Message Codes

Meaning/Problem
Code
07
Source empty
10
Cassette present
intermittently blocked
12
Illegal SCSI ID
15
Unexpected pick arm out
position
16
Unexpected magazine
home position
21
No arm out position
detected
23
Unexpected cassette
sensor block
25
Unable to retrieve cassette
32
Load cassette failure
37
Reverse cassette failure
Reset DAT Autochanger and reload magazine.
beam
Check that cassette present sensor is not
inadvertently blocked by foreign object.
Change SCSI ID to valid ID using the rear
panel switch.
Check to see if there is something obstructing
arm. Remove it and reset DAT Autochanger.
Check to see that magazine is seated correctly
and that nothing is obstructing its movement.
If there appears to be no obstruction, unload
magazine and reload it from front panel.
Check to see if there is something obstructing
arm. Remove it and reset DAT Autochanger.
Check for foreign material obstructing
cassette-present beam and remove as
necessary. Check to see that magazine is
seated correctly and that nothing is obstructing
its movement. If there appears to be no
obstruction, unload magazine and reload it.
Check that the cassette sliding door is not
staying open.
Check to make sure cassette is inserted in the
magazine correctly and that nothing is
obstructing it from moving into the drive.
Make sure that the cassette is inserted in the
magazine correctly. All the write-protect tabs
should be facing you at the upper right.
Troubleshooting and Diagnostics
Action
Mode of
Operation
Sequential
Sequential
Random
Sequential
Sequential
Sequential
Sequential
Sequential
Sequential
Sequential
35