Flash Off Time

This feature specifies the OFF time for the indicator LED while in Flash Mode. The se-
lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in-
crements.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
4. Scan the barcode: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
This completes the procedure. See
Table 6. Flash Off Time Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad with
2
leading zeroes to yield two digits)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH OFF TIME SETTING
Scan Two Characters From
5
Appendix E, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
ming Mode.
sent the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
ming Mode.
500ms
05
'0' and '5'
Appendix E,
Table 6
for some examples of how to set this feature.
EXAMPLES
1,000ms (1 sec.) 5200ms (5.2 sec.)
10
'1' and '0'
'5' and '2'
Flash Off Time
Keypad, that repre-
9,900ms (9.9 sec.)
52
99
'9' and '9'
39