Ack Nak Retry Count - Datalogic PowerScan PD7100 Corded Product Reference Manual

Linear imaging barcode reader
Hide thumbs Also See for PowerScan PD7100 Corded:
Table of Contents

Advertisement

RS-232/USB-Com Interfaces

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due
to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0
disables the count, and a selection of 255 specifies unlimited retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 =
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
This completes the procedure. See
feature.
Table 11. ACK NAK Retry Count Setting Examples
STEP
ACTION
1
Desired Setting
2
Pad with leading zero(es)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK RETRY COUNT SETTING
Scan Three Characters From
5
Appendix E, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
64
005, 20 = 020, etc.
ming Mode.
represent the number which was determined in the steps above. You will hear a
two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
ming Mode.
Disable Retry
Count
000
'0', '0' and '0'
Appendix E, Keypad
for some examples of how to set this
Table 11
EXAMPLES
3 Retries
54 Retries
003
054
'0', '0' and '3'
'0', '5' and '4'
PowerScan
, that
Unlimited Retries
255
'2', '5' and '5'
®
PD7100 Corded

Advertisement

Table of Contents
loading

Table of Contents