Intercode Delay - Datalogic PowerScan PD7100 Corded Product Reference Manual

Linear imaging barcode reader
Hide thumbs Also See for PowerScan PD7100 Corded:
Table of Contents

Advertisement

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The selectable
range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 =
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
4. Scan the barcode: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
This completes the procedure. See
Table 16. Wedge Intercode Delay Examples
STEP
ACTION
1
Desired Setting
2
Pad with leading zero(es)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCODE DELAY SETTING
Scan Two Characters From
5
Appendix E, Keypad
7
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
05, 20 = 20, etc
ming Mode.
resent the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
ming Mode.
No Delay
00
'0' and '0'
Appendix E, Keypad
for some examples of how to set this feature.
Table 16
EXAMPLES
5 Seconds
60 Seconds
05
'0' and '5'
'6' and '0'
Intercode Delay
, that rep-
99 Seconds
60
99
'9' AND '9'
83

Advertisement