Industrial corded and cordless handheld area imager bar code reader (360 pages)
Summary of Contents for Datalogic PowerScan PD9530-HP
Page 1
PowerScan™ PD9530 Industrial Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...
Page 2
Datalogic has taken reasonable measures to provide informa- tion in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
2. Scope Of License Granted 2.1 Datalogic grants to End User a personal non-exclusive, non-transferable, per- petual license to use the Software, solely on the Datalogic Product in which it is embedded ("designated Datalogic Product"), in machine-readable form only, solely for End User's internal business purposes. This Agreement does not convey ownership of the Software to End User.
Page 6
3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or other- wise transfer the Datalogic Product to any third party unless such third party agrees with Datalogic in writing to be bound by the terms and conditions of this Agreement. Any such transfer of the Datalogic Product absent such agreement shall be null and void.
Page 7
52.227-19 or in the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), whichever is applicable. 9.2 If End User is using the Datalogic Product outside of the United States, End User must comply with the applicable local laws of the country in which the Datalogic Product is used, with U.S.
The Court of Hong Kong shall have exclusive jurisdiction over all matters regarding this Agreement, except that Datalogic shall have the right, at its absolute discretion, to initiate pro- ceedings in the courts of any other state, country, or territory in which End User resides, or in which any of End User's assets are located.
PowerScan™ PD9530 Description The PowerScan™ 9530 is a feature-rich and rugged area imager reader. It is offered in several different models to better fit the different needs of each customer. The table below shows the unique features of each model: Model P/N Optical feature PD9530...
USA Driver License PDF417 barcodes. This feature can be USA Driver License enabled using either Datalogic Aladdin™ or Parsing the barcodes in the USA Driver License Pars- ing Quick Reference Guide (QRG), available on the Datalogic website.
Setting Up the Reader Connecting the Cable A. Rubber gasket B. Cable Holder C. Cover D. Connector Holder Slip the cable through the Cover. Push the Rubber Gas- ket onto the Cable FRONT>> Holder. Push the Cable Holder and gasket into the handle.
Using the PowerScan™ PD9530 Using the PowerScan™ PD9530 The PowerScan™ PD9530 normally functions by capturing and decoding bar codes. The reader is equipped with an internal Motionix™ motion-sensing function which acti- vates the aiming system on device motion. The intelligent aiming system indicates the field of view which should be positioned over the bar code: Table 1.
Selecting the Interface Type Selecting the Interface Type Upon completing the physical connection between the reader and its host, proceed directly to Interface Selection below for information and programming for the interface type the reader is connected to (for example: RS-232, Key- board Wedge, USB, etc.) and scan the appropriate bar code to select your system’s correct interface type.
Page 14
Selecting the Interface Type RS-232 RS-232 standard interface RS-232 RS-232 Wincor-Nixdorf RS232-WN RS-232 for use with OPOS/UPOS/JavaPOS RS-232 OPOS USB Com to simulate RS-232 standard interface USB-COM PowerScan™ PD9530...
Page 15
Selecting the Interface Type USB (continued) USB-OEM (can be used for OPOS/UPOS/JavaPOS) USB-OEM a. Download the correct USB Com driver from www.datalogic.com USB Keyboard with standard key encoding USB-KBD USB Keyboard with alternate key encoding USB-KBD-ALT USB Keyboard for Apple computers...
Selecting the Interface Type Keyboard Interface KEYBOARD WEDGE IBM AT or PS/2 PCs Standard Key Encoding KBD-AT IBM AT or PS/2 PCs Standard Key Encoding without external keyboard KBD-AT-NK IBM AT or PS/2 PCs w/Alternate Key KBD-AT-ALT IBM AT or PS/2 PCs Alternate Key Encoding without external keyboard KBD-AT-ALT-NK Scancode Tables...
Selecting the Interface Type Country Mode This feature specifies the country/language supported by the keyboard. This option is usable only with USB-KBD and Keyboard Wedge interface without the "Alternate Key" mode. COUNTRY MODE ENTER/EXIT PROGRAMMING MODE Country Mode = U.S. Country Mode = Belgium Country Mode = Britain Country Mode = Croatia*...
Page 18
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Czech* Country Mode = Denmark* Country Mode = France $CKBCO13(CR) Country Mode = French Canadian* Country Mode = Germany Country Mode = Hungary* *Supports only the interfaces listed in the Country Mode feature description PowerScan™...
Page 19
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Italy Country Mode = Japanese 106-key* Country Mode = Lithuanian* Country Mode = Norway* Country Mode = Poland* Country Mode = Portugal* *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide...
Page 20
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Romania* Country Mode = Spain Country Mode = Sweden Country Mode = Slovakia* Country Mode = Switzerland* *Supports only the interfaces listed in the Country Mode feature description PowerScan™ PD9530...
Selecting the Interface Type Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding key- board is selected. ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable...
Selecting the Interface Type Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard. ENTER/EXIT PROGRAMMING MODE Numlock = Numlock key unchanged Numlock = Numlock key toggled PowerScan™...
Programming Programming The reader is factory-configured with a set of standard default features. After scanning the interface bar code from the Interfaces section, select other options and cus- tomize your reader through use of the programming bar codes available in the PowerScan™ PD9530. Check the cor- responding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
Reading Parameters Reading Parameters Move the reader toward the target and center the aiming pattern and illumination system to capture and decode the image. See Using the PowerScan™ PD9530 on page 4 for more information. The aiming system will briefly switch off after the acquisi- tion time, and if no code is decoded will switch on again before the next acquisition.
Operating Modes Operating Modes Scan Mode The imager can be set to operate in one of several scan- ning modes. See the PRG for more information and set- tings for any of the options: Trigger Single (Default) — This mode is associated with typi- cal handheld reader operation.
Operating Modes Scan Mode (continued) ENTER/EXIT PROGRAMMING MODE Scan Mode = Trigger Single Scan Mode = Trigger Pulse Multiple Scan Mode = Trigger Hold Mul- Scan Mode = Flashing tiple Scan Mode = Always On Scan Mode = Stand Mode Motion Aiming Control This feature configures the ability of the scanner to Enable/Disable the Aiming system when motion is...
Operating Modes Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. Pick Mode is a Decoding and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowl- edged or transmitted to the host.
Technical Specifications Technical Specifications The following table contains Physical and Performance Characteristics, User Environment and Regulatory infor- mation. Item Description Physical Characteristics Height: 212 mm Dimensions Length: 110 mm Width: 74 mm Weight (without 330 gr (without cable) cable) Electrical Characteristics PD9530/ Voltage &...
Page 29
Technical Specifications Performance Characteristics Light Source Roll (Tilt) Tolerance ± 180° Pitch Tolerance ± 40° Skew (Yaw) Toler- ± 40° ance Print Contrast 15% minimum Minimum reflectance PD9530-HP / PD9530 PD9530-HPE Max resolution 1D 4 mils 1D 2.5 mil Resolution Max resolution 2D 2D 4 mil 7.5 mils...
Page 30
Technical Specifications Decode Capability 1D Bar Codes GS1 Databar linear codes, UPC/EAN (A,E,13,8), UPC/EAN with P2/ P5 Addons, UPC/EAN Coupons, ISBN, Code128, EAN128, ISBT128, Code39, Code39 Full ASCII, Code39 CIP, Code 32, Codabar, Inter- leaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, Code11, MSI, Plessey, Code 93, Follet 2/5 2D / Stacked Codes DataMatrix, MaxiCode and QR Codes(QR, Micro QR and Multiple QR...
LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s func- tions are programmable, and so may or may not be turned on.
Page 32
LED and Beeper Indications Indicator Description Beeper Upon success- ful read of a label, the soft- Green Spot ware shall turn flashes the green spot momentarily on for the time specified by the configured value. Blue light Image Cap- When ready to flashes 2 times ture capture image...
Page 33
LED and Beeper Indications Programming Mode The following indications ONLY occur when the reader is in Programming Mode INDICATION DESCRIPTION BEEPER Label Pro- A valid program- Reader sounds LED blinks four low fre- gramming ming label has continuously Mode Entry been scanned.
Error Codes Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. Press and release the trigger to hear the FRU indication code.
Cleaning Cleaning Exterior surfaces and scan windows exposed to spills, smudges or debris require periodic cleaning to ensure best performance during scanning. Use a soft, dry cloth to clean the product. If the product is very soiled, clean it with a soft cloth moistened with a diluted non-aggressive cleaning solution or diluted ethyl alcohol.
Datalogic service center, with shipping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Da-...
Page 37
No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic. DATALOGIC' S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATU- TORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT.
Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of specific writ- ten instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
Support Through the Website Support Through the Website Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the SUPPORT > Industrial Handheld Scanners category link. From this page you can select your product model from the drop-...
Page 40
Support Through the Website PowerScan™ PD9530...