Datalogic Powerscan PD7100 Product Reference Manual

Datalogic Powerscan PD7100 Product Reference Manual

Industrial corded handheld linear imager bar code reader
Hide thumbs Also See for Powerscan PD7100:
Table of Contents

Advertisement

TM
PowerScan
PD7100
Industrial Corded Handheld Linear Imager Bar Code Reader
Product Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic Powerscan PD7100

  • Page 1 PowerScan PD7100 Industrial Corded Handheld Linear Imager Bar Code Reader Product Reference Guide...
  • Page 2 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic"...
  • Page 3: Table Of Contents

    Manual Overview ........................1 Manual Conventions ....................... 2 References ..........................2 Technical Support ........................3 Datalogic Website Support ....................3 Reseller Technical Support ....................3 Telephone Technical Support ....................3 Chapter 2. Getting Started ......................5 About the Reader ........................5 Unpacking ..........................
  • Page 4 Green Spot Duration ......................44 Chapter 5. RS-232 ONLY Interface................... 45 Introduction ......................... 45 RS-232 Standard Factory Settings ..................45 Baud Rate ........................... 45 Data Bits ..........................47 Stop Bits ..........................48 Parity ..........................49 Handshaking Control ......................50 Chapter 6. RS-232/USB-Com Interfaces .................. 51 Introduction .........................
  • Page 5 Wand Signal Speed .......................97 Label Symbology Conversion ....................98 Transmit Noise ........................99 Chapter 11. Data Editing ......................101 Data Editing Overview ......................101 Please Keep In Mind......................102 Global Prefix/Suffix ......................102 Example: Setting a Prefix ....................102 Global AIM ID ........................104 GS1-128 AIM ID .........................
  • Page 6 Optional Add-On Timer ....................148 Optional GS1-128 Add-On Timer ..................151 P2 Add-Ons Minimum Reads ................... 154 P5 Add-Ons Minimum Reads ................... 155 GS1-128 Add-Ons Minimum Reads .................. 156 GS1 DataBar Omnidirectional .................... 157 GS1 DataBar Omnidirectional Enable/Disable ..............157 GS1 DataBar Omnidirectional GS1-128 Emulation .............
  • Page 7 Interleaved 2 of 5 CIP HR Enable/Disable ................215 Datalogic 2 of 5 ........................215 Datalogic 2 of 5 Enable/Disable ..................215 Datalogic 2 of 5 Check Character Calculation ..............216 Datalogic 2 of 5 Minimum Reads ..................217 Datalogic 2 of 5 Decoding Level ..................217 Datalogic 2 of 5 Length Control ..................
  • Page 8 Standard 2 of 5 Decoding Level ..................265 Standard 2 of 5 Length Control ..................266 Standard 2 of 5 Set Length 1 ..................267 Standard 2 of 5 Set Length 2 ..................269 Standard 2 of 5 Character Correlation ................271 Standard 2 of 5 Stitching ....................
  • Page 9 Codablock F AIM Check ....................320 Codablock F Length Control .................... 321 Codablock F Set Length 1 ....................322 Codablock F Set Length 2 ....................324 Code 4 ..........................326 Code 4 Enable/Disable ....................326 Code 4 Check Character Transmission ................327 Code 4 Hex to Decimal Conversion ...................
  • Page 10 PowerScan PD7100 Corded...
  • Page 11: Chapter 1. Introduction

    Programming can alternatively be performed using the Datalogic Aladdin™ Configura- tion application which is downloadable from the Datalogic website listed on the back cover of this manual. This multi-platform utility program allows device configuration us- ing a PC.
  • Page 12: Manual Conventions

    References Current versions of the Product Reference Guide (PRG), Quick Reference Guide (QRG), the Datalogic Aladdin™ Configuration application, and any other manuals, in- struction sheets and utilities for this product can be downloaded from the website listed on the back cover of this manual. Alternatively, printed copies or product support CDs can be purchased through your Datalogic reseller.
  • Page 13: Technical Support

    Telephone Technical Support If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information.
  • Page 14 Introduction NOTES PowerScan PD7100 Corded...
  • Page 15: Chapter 2. Getting Started

    Chapter 2 Getting Started About the Reader Advancements in the LED technology used in this reader significantly improve the illumination of the target field of view, resulting in higher scan efficiency. Whether used in Single Trigger or Continuous Mode, the ergonomic design of the reader will help to promote comfortable han- dling during extended periods of use.
  • Page 16: Setting Up The Reader

    Getting Started Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host: Install the Interface Cable Select the Interface Type Configure Interface Settings (only if not using factory settings for that interface) Configure Other Features (if modifications are needed from factory settings) Install the Interface Cable...
  • Page 17: Programming

    Setting Up the Reader Other connection types are described below and illustrated in Figure USB Connection — Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure IBM Connection —...
  • Page 18: Using The Programming Barcodes

    Getting Started Using the Programming Barcodes This manual contains feature descriptions and barcodes which allow you to reconfigure your reader. Some programming barcode labels, like the Resetting the Product Configuration to Defaults on page 9, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the reader to be placed in Programming Mode prior to scanning them.
  • Page 19: Software Version Transmission

    Resetting the Product Configuration to Defaults Software Version Transmission The software version of the device can be transmitted over the RS-232 and Keyboard in- terfaces by scanning the following label. Transmit Software Version Resetting the Product Configuration to Defaults If you aren't sure what programming options are in your imager, or you've changed some options and want to restore the Custom Default Configuration that may have been saved in the imager, scan the Restore Custom Default Configuration...
  • Page 20 Getting Started NOTES PowerScan PD7100 Corded...
  • Page 21: Chapter 3. Interfaces

    Chapter 3 Interfaces Interface Selection Each reader model will support one of the following sets of host interfaces: General Purpose Models (5 volt supply) RS-232 RS-232 OPOS Keyboard Wedge Wand Emulation Retail Point of Sale Models (4 to 14 volt supply) RS-232 RS-232 OPOS IBM 46XX...
  • Page 22 89 IBM-46xx Port 9B reader interface Select IBM-P9B USB-OEM FEATURES Set USB-OEM Interface USB-OEM Features (can be used for OPOS/UPOS/JavaPOS) starting on page 85 Select USB-OEM a. Download the correct USB Com driver from www.datalogic.com PowerScan PD7100 Corded...
  • Page 23 Configuring the Interface KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 Set KEYBOARD w/Alternate Key WEDGE...
  • Page 24 Interfaces KEYBOARD — cont. FEATURES Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Set KEYBOARD WEDGE Select KBD-DIG-VT...
  • Page 25: Global Interface Features

    Global Interface Features Global Interface Features The following interface features are configurable by all interface types. To set features specific to your interface, turn to that section of this manual: • RS-232 ONLY Interface on page 45 • Keyboard Interface on page 71 •...
  • Page 26: Usb Suspend Mode

    Interfaces USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode. ENTER/EXIT PROGRAMMING MODE DEFAULT USB Suspend Mode = Disable USB Suspend Mode = Enable PowerScan PD7100 Corded...
  • Page 27: Chapter 4. General Features

    Chapter 4 General Features Double Read Timeout To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Double Read Timeout, the second read of the label will be ignored.
  • Page 28 General Features Double Read Timeout — continued ENTER/EXIT PROGRAMMING MODE Double Read Timeout = 0.5 Second Double Read Timeout = 0.6 Second Double Read Timeout = 0.7 Second Double Read Timeout = 0.8 Second Double Read Timeout = 0.9 Second Double Read Timeout = 1 Second PowerScan PD7100 Corded...
  • Page 29: Label Gone Timeout

    Label Gone Timeout Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 millisec- onds (2.55 seconds) in 10ms increments.
  • Page 30 General Features Label Gone Timeout — cont. ENTER/EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 016 = Timeout of 160 ms DEFAULT PowerScan PD7100 Corded...
  • Page 31: Sleep Mode Timeout

    Sleep Mode Timeout Sleep Mode Timeout Specifies the timeout value for the reader to enter low power Sleep Mode. ENTER/EXIT PROGRAMMING MODE DEFAULT Sleep Mode Timeout = Disable Sleep Mode Timeout = 500ms Sleep Mode Timeout = 1 Second Sleep Mode Timeout = 2 Seconds Sleep Mode Timeout = 3 Seconds Sleep Mode Timeout = 4 Seconds Product Reference Guide...
  • Page 32 General Features Sleep Mode Timeout — continued ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout = 5 Seconds Sleep Mode Timeout = 6 Seconds Sleep Mode Timeout = 7 Seconds Sleep Mode Timeout = 8 Seconds Sleep Mode Timeout = 9 Seconds Sleep Mode Timeout = 9.9 Seconds (9,900ms max.) PowerScan PD7100 Corded...
  • Page 33: Led And Beeper Indicators

    LED and Beeper Indicators LED and Beeper Indicators Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. ENTER/EXIT PROGRAMMING MODE Power On Alert = Disable (No Audible Indication) DEFAULT Power On Alert = Four Beeps Product Reference Guide...
  • Page 34: Good Read: When To Indicate

    General Features Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit •...
  • Page 35: Good Read Beep Type

    LED and Beeper Indicators Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. ENTER/EXIT PROGRAMMING MODE DEFAULT Good Read Beep Type = Mono Good Read Beep Type = Bitonal Product Reference Guide...
  • Page 36: Good Read Beep Frequency

    General Features Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, se- lectable from the list below. (Controls the beeper’s pitch/tone.) ENTER/EXIT PROGRAMMING MODE Good Read Beep Frequency = Low Good Read Beep Frequency = Medium DEFAULT Good Read Beep Frequency = High...
  • Page 37 LED and Beeper Indicators Good Read Beep Length — continued ENTER/EXIT PROGRAMMING MODE DEFAULT Good Read Beep Length = 80 msec Good Read Beep Length = 100 msec Good Read Beep Length = 120 msec Good Read Beep Length = 140 msec Good Read Beep Length = 160 msec Good Read Beep Length = 180 msec Good Read Beep Length = 200 msec...
  • Page 38: Good Read Beep Volume

    General Features Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. ENTER/EXIT PROGRAMMING MODE Good Read Beep Volume = Beeper Off Good Read Beep Volume = Low Good Read Beep Volume = Medium DEFAULT Good Read Beep Volume = High PowerScan...
  • Page 39: Good Read Led Duration

    LED and Beeper Indicators Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 100 milliseconds to 25.5 seconds (0.1 to 25.5 seconds) in 100ms increments.
  • Page 40 General Features Good Read LED Duration — cont. ENTER/EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 020 = Good Read LED stays on for DEFAULT...
  • Page 41: Scanning Features

    Scanning Features Scanning Features Scan Mode Selects the scan operating mode for the reader. Selections are: Trigger Single — When the trigger is pulled, scanning is activated until one of the fol- lowing occurs: Scanning Active Time has elapsed - a label has been read - the trigger is released This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read,...
  • Page 42 General Features Scan Mode — continued ENTER/EXIT PROGRAMMING MODE DEFAULT Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode Scan Mode = Trigger Object Sense PowerScan PD7100 Corded...
  • Page 43: Stand Mode Triggered Timeout

    Scanning Features Stand Mode Triggered Timeout This feature specifies the time to remain in mode after the trigger is pulled Trigger Single while in Stand Mode. Stand This timeout is only used when the Scan Mode is configured as Mode. NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT...
  • Page 44 General Features Stand Mode Triggered Timeout — continued ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout = 6 Seconds Stand Mode Triggered Timeout = 8 Seconds Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull PowerScan PD7100 Corded...
  • Page 45: Scanning Active Time

    Scanning Features Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre- ments. Follow these instructions to set this feature: 1.
  • Page 46 General Features Scanning Active Time — cont. ENTER/EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 005 = Scanning is active for 5 Seconds PowerScan PD7100 Corded...
  • Page 47: Flash On Time

    Flash On Time Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements. Follow these instructions to set this feature. 1.
  • Page 48 General Features Flash On Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 10 = Flash is ON for 1 Second DEFAULT PowerScan PD7100 Corded...
  • Page 49: Flash Off Time

    Flash Off Time Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The se- lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in- crements. Follow these instructions to set this feature. 1.
  • Page 50 General Features Flash Off Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 06 = Flash is OFF for 600ms DEFAULT PowerScan PD7100 Corded...
  • Page 51: Stand Mode Sensitivity

    Stand Mode Sensitivity Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. ENTER/EXIT PROGRAMMING MODE Stand Mode Sensitivity = Low DEFAULT Stand Mode Sensitivity = Medium Stand Mode Sensitivity = High Product Reference Guide...
  • Page 52: Laser Pointer Control

    General Features Laser Pointer Control The Laser Pointer is a value-added option which might not have been included when your reader was ordered. NOTE Specifies the amount of time that the laser pointer is turned on preliminary to scanning. When the trigger is pressed in Trigger Single Mode, the laser pointer will be activated for the time period configured by this feature.
  • Page 53: Laser Pointer Period

    Laser Pointer Period Laser Pointer Period This option specifies the period of the laser pointer blink during scanning. The laser pointer will be activated for the time specified by then start blinking Laser Pointer Control OFF then ON at a 50% duty cycle and a repeating period set by Laser Pointer Period.
  • Page 54: Green Spot Duration

    General Features Green Spot Duration Specifies the duration of the good read pointer beam after a good read. ENTER/EXIT PROGRAMMING MODE Green Spot Duration = Disable (Green Spot is Off) DEFAULT Green Spot Duration = Short (300 msec) Green Spot Duration = Medium (500 msec) Green Spot Duration = Long (800 msec) PowerScan PD7100 Corded...
  • Page 55: Chapter 5. Rs-232 Only Interface

    Chapter 5 RS-232 ONLY Interface Introduction Use the programming barcodes in this chapter if modifications to the standard RS- 232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 6, RS-232/USB-Com Interfaces RS-232 Standard Factory Settings...
  • Page 56 RS-232 ONLY Interface Baud Rate — continued ENTER/EXIT PROGRAMMING MODE DEFAULT Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 Baud Rate = 115,200 PowerScan PD7100 Corded...
  • Page 57: Data Bits

    Data Bits Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. ENTER/EXIT PROGRAMMING MODE 7 Data Bits DEFAULT 8 Data Bits Product Reference Guide...
  • Page 58: Stop Bits

    RS-232 ONLY Interface Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate.
  • Page 59: Parity

    Parity Parity This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select None when no parity bit is required. •...
  • Page 60: Handshaking Control

    RS-232 ONLY Interface Handshaking Control The data interface consists of an RS-232 port designed to operate either with or with- out the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options: •...
  • Page 61: Chapter 6. Rs-232/Usb-Com Interfaces

    Chapter 6 RS-232/USB-Com Interfaces Introduction The programming barcodes in this chapter allow modifications to the standard RS- 232 and USB-Com interfaces. Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Product Reference Guide...
  • Page 62: Intercharacter Delay

    RS-232/USB-Com Interfaces Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1.
  • Page 63 Intercharacter Delay Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Intercharacter Delay DEFAULT...
  • Page 64: Beep On Ascii Bel

    RS-232/USB-Com Interfaces Beep On ASCII BEL When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event. ENTER/EXIT PROGRAMMING MODE DEFAULT Beep On ASCII BEL = Disable...
  • Page 65: Ack Nak Options

    ACK NAK Options ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK pro- tocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: •...
  • Page 66: Ack Character

    RS-232/USB-Com Interfaces ACK Character This setting specifies an ASCII character or hex value to be used as the ACK charac- ter. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 67 ACK NAK Options ACK Character — cont. ENTER/EXIT PROGRAMMING MODE Select ACK Character Setting 0x06 ‘ACK’ Character DEFAULT Product Reference Guide...
  • Page 68: Nak Character

    RS-232/USB-Com Interfaces NAK Character This setting specifies an ASCII character or hex value to be used as the NAK charac- ter. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 69 ACK NAK Options NAK Character — cont. ENTER/EXIT PROGRAMMING MODE Select NAK Character Setting 0x15 ‘NAK’ Character DEFAULT Product Reference Guide...
  • Page 70: Ack Nak Timeout Value

    RS-232/USB-Com Interfaces ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 millisec- onds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
  • Page 71 ACK NAK Options ACK NAK Timeout Value — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 ACK NAK Timeout value is 200ms DEFAULT...
  • Page 72: Ack Nak Retry Count

    RS-232/USB-Com Interfaces ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1.
  • Page 73 ACK NAK Options ACK NAK Retry Count — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 003 = 3 Retries DEFAULT...
  • Page 74: Ack Nak Error Handling

    RS-232/USB-Com Interfaces ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host. Options are: • Ignore errors detected • Process error as valid ACK character •...
  • Page 75: Indicate Transmission Failure

    Indicate Transmission Failure Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode. ENTER/EXIT PROGRAMMING MODE Indicate Transmission Failure = Disable Indication DEFAULT Indicate Transmission Failure = Enable Indication Product Reference Guide...
  • Page 76: Disable Character

    RS-232/USB-Com Interfaces Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 77 Disable Character Disable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Disable Character Setting 0x44 = Disable Character is ‘D’ DEFAULT Product Reference Guide...
  • Page 78: Enable Character

    RS-232/USB-Com Interfaces Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 79 Enable Character Enable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Enable Character Setting 0x45 = Enable Character is ‘E’ DEFAULT Product Reference Guide...
  • Page 80 RS-232/USB-Com Interfaces NOTES PowerScan PD7100 Corded...
  • Page 81: Chapter 7. Keyboard Interface

    Chapter 7 Keyboard Interface Introduction Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Scancode Tables Information about control character emulation which applies to keyboard interfaces is listed in Appendix F, Scancode Tables Product Reference Guide...
  • Page 82: Country Mode

    Keyboard Interface Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. • USB Keyboard (without alternate key encoding) • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding •...
  • Page 83 Country Mode Country Mode — continued ENTER/EXIT PROGRAMMING MODE Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Denmark Country Mode = France Country Mode = Germany Supports only the interfaces listed in theCountry Mode feature description.
  • Page 84 Keyboard Interface Country Mode — continued ENTER/EXIT PROGRAMMING MODE Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Poland Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Portugal Supports only the interfaces listed in theCountry Mode feature description.
  • Page 85: Caps Lock State

    Caps Lock State Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. ENTER/EXIT PROGRAMMING MODE DEFAULT Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable...
  • Page 86: Send Control Characters

    Keyboard Interface Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the host. Ref- erence for more information about control characters. Appendix F, Scancode Tables Options are as follows: Control Character 00 — Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
  • Page 87: Wedge Quiet Interval

    Wedge Quiet Interval Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the read- er breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface.
  • Page 88 Keyboard Interface Wedge Quiet Interval — cont. ENTER/EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 10 = Quiet Interval of 100 ms DEFAULT PowerScan PD7100 Corded...
  • Page 89: Intercharacter Delay

    Intercharacter Delay Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface.
  • Page 90 Keyboard Interface Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Intercharacter Delay DEFAULT...
  • Page 91: Intercode Delay

    Intercode Delay Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2.
  • Page 92 Keyboard Interface Intercode Delay — cont. ENTER/EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Wedge Intercode Delay DEFAULT PowerScan PD7100 Corded...
  • Page 93: Usb Keyboard Speed

    USB Keyboard Speed USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface. NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT USB Keyboard Speed = 1ms USB Keyboard Speed = 2ms USB Keyboard Speed = 3ms USB Keyboard Speed = 4ms USB Keyboard Speed = 5ms...
  • Page 94 Keyboard Interface USB Keyboard Speed — continued ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed = 6ms USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms PowerScan PD7100 Corded...
  • Page 95: Chapter 8. Usb-Oem Interface

    Chapter 8 USB-OEM Interface Introduction Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and Chapter 9, IBM 46XX to specifically configure for the USB-OEM interface. Other USB interfaces are Interface included in the approprite chapter for their host type.
  • Page 96: Usb-Oem Device Usage

    USB-OEM Interface USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have con- nected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate.
  • Page 97: Usb-Oem Interface Options

    USB-OEM Interface Options USB-OEM Interface Options This setting provides for an interface specific control mechanism.. Options are: • Obey — Obey Scanner Configuration Host Commands • Ignore — Ignore Scanner Configuration Host Commands ENTER/EXIT PROGRAMMING MODE USB-OEM Interface Options = Obey DEFAULT USB-OEM Interface Options = Ignore Product Reference Guide...
  • Page 98 USB-OEM Interface NOTES PowerScan PD7100 Corded...
  • Page 99: Chapter 9. Ibm 46Xx Interface

    Chapter 9 IBM 46XX Interface Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. IBM Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Product Reference Guide...
  • Page 100: 46Xx Number Of Host Resets

    IBM 46XX Interface 46xx Number of Host Resets Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The con- figurable range for this feature is 1 to 15 resets. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 1 46xx Number of Host Resets = 2...
  • Page 101 46xx Number of Host Resets 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 7 46xx Number of Host Resets = 8 46xx Number of Host Resets = 9 46xx Number of Host Resets = 10 46xx Number of Host Resets = 11 46xx Number of Host Resets = 12 Product Reference Guide...
  • Page 102 IBM 46XX Interface 46xx Number of Host Resets — cont. ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 13 46xx Number of Host Resets = 14 46xx Number of Host Resets = 15 PowerScan PD7100 Corded...
  • Page 103: Transmit Labels In Code 39 Format

    Transmit Labels in Code 39 Format Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to an IBM-46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39. Options are: IBM Standard Format —...
  • Page 104: Ibm 46Xx Interface Options

    IBM 46XX Interface IBM 46XX Interface Options This setting provides for an interface specific control mechanism.. Options are: • Obey — Obey Scanner Configuration Host Commands • Ignore — Ignore Scanner Configuration Host Commands ENTER/EXIT PROGRAMMING MODE USB-OEM Interface Options = Obey DEFAULT USB-OEM Interface Options = Ignore PowerScan...
  • Page 105: Chapter 10. Wand Emulation Interface

    Chapter 10 Wand Emulation Interface Introduction This chapter provides feature/settings configuration for the Wand Emulation interface. Wand Emulation Standard Factory Settings Reference for a listing of standard factory settings. Appendix B, Standard Defaults Wand Idle State This feature specifies the level of the Wand output signal when the reader is idle. TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V...
  • Page 106: Wand Polarity

    Wand Emulation Interface Wand Polarity This option specifies the polarity of the Wand output signal. Choices are: • Quiet zones and spaces are high, bars are low • Quiet zones and spaces are low, bars are high TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V NOTE...
  • Page 107: Wand Signal Speed

    Wand Signal Speed Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds ENTER/EXIT PROGRAMMING MODE Wand Signal Speed = 330ms DEFAULT Wand Signal Speed = 660ms Product Reference Guide...
  • Page 108: Label Symbology Conversion

    Wand Emulation Interface Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are: • No conversion • Convert to Code 39 symbology • Convert to Code 39 Full ASCII •...
  • Page 109: Transmit Noise

    Transmit Noise Transmit Noise This option specifies the leading/trailing noise for the Wand interface. Choices are: • Disable (no leading/trailing noise) • Enable leading noise • Enable trailing noise • Enable leading and trailing noise ENTER/EXIT PROGRAMMING MODE DEFAULT Transmit Noise = Disable Transmit Noise = Transmit leading noise Transmit Noise = Transmit trailing noise Transmit Noise = Transmit leading and trailing noise...
  • Page 110 Wand Emulation Interface NOTES PowerScan PD7100 Corded...
  • Page 111: Chapter 11. Data Editing

    ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII) Additional advanced editing is available. See the Advanced Formatting fea- Technical tures in the Datalogic Aladdin Configuration Application or contact Support on page 3 for more information. NOTE Product Reference Guide...
  • Page 112: Please Keep In Mind

    Data Editing Please Keep In Mind... • Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Fac- tory default settings for data editing is typically set to NONE. •...
  • Page 113 Global Prefix/Suffix 5. If less than the expected string of 20 characters are selected, scan the ENTER/ EXIT barcode to terminate the string. 6. Scan the ENTER/EXIT barcode once again to exit Programming Mode. 7. The resulting message string would appear as follows: Scanned barcode data:12345 Resulting message string output: $12345 This option sets up to 20 characters each from the set of ASCII characters or any hex val-...
  • Page 114: Global Aim Id

    Data Editing Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. NOTE AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: •...
  • Page 115 Global AIM ID Global AIM ID — continued ENTER/EXIT PROGRAMMING MODE DEFAULT Global AIM ID = Disable Global AIM ID = Enable Product Reference Guide...
  • Page 116: Gs1-128 Aim Id

    Data Editing GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled inde- pendently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance.
  • Page 117: Label Id

    Label ID Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a barcode (symbology) type. It can be appended previ- ous to or following the transmitted barcode data depending upon how this option is en- abled.
  • Page 118 230000 540000 CODE32 410000 580000 CODE39 2A0000 560000 CODE4 340000 340000 CODE5 6A0000 6A0000 CODE93 & 260000 550000 DATALOGIC 2OF5 730000 730000 EAN13 460000 420000 EAN13 P2 460000 4C0000 EAN13 P5 460000 4D0000 EAN13 P8 460000 230000 EAN8 464600 410000...
  • Page 119 Label ID Symbology USA Label ID set EU Label ID set GTIN5 473500 244300 GTIN8 473800 244400 I2OF5 690000 4E0000 IATA 494100 & 260000 Industrial 2 of 5 570000 570000 Interleaved 2 of 5 CIP HR 650000 650000 ISBN 490000 400000 ISBT128 660000...
  • Page 120: Label Id: Set Individually Per Symbology

    Data Editing Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Scan the ENTER/EXIT barcode. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suffix) by scanning the appropriate barcode in the section Label ID Control on .
  • Page 121 Label ID Label ID — continued Table 18. Label ID Examples STEP ACTION EXAMPLES Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned data using Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix...
  • Page 122: Label Id Control

    Data Editing Label ID — continued Label ID Control This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type. ENTER/EXIT PROGRAMMING MODE DEFAULT Label ID Transmission = Disable Label ID Transmission = Enable as Prefix Label ID Transmission = Enable as Suffix Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 123: Label Id Symbology Selection

    Label ID Label ID — continued Label ID Symbology Selection This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set UPC-A Label ID Character(s) Set UPC-A/P2 Label ID Character(s) Set UPC-A/P5 Label ID Character(s) Set UPC-A/GS1-128 Label ID Character(s)
  • Page 124 Data Editing Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set UPC-E/P5 Label ID Character(s) Set UPC-E/GS1-128 Label ID Character(s) Set EAN 13 Label ID Character(s) Set EAN 13/P2 Label ID Character(s)
  • Page 125 Label ID Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set EAN 8 Label ID Character(s) Set EAN 8/P2 Label ID Character(s) Set EAN 8/P5 Label ID Character(s) Set EAN 8/GS1-128 Label ID Character(s)
  • Page 126 Data Editing Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set GTIN/P5 Label ID Character(s) Set GTIN/GS1-128 Label ID Character(s) Set GS1 DataBar Omnidirectional Label ID Character(s) Set GS1 DataBar Expanded Label ID Character(s)
  • Page 127 Set Code 128 Label ID Character(s) Set GS1-128 Label ID Character(s) Set Interleaved 2 of 5 Label ID Character(s) Set Interleaved 2 of 5 CIP HR Label ID Character(s) Set Datalogic 2 of 5 Label ID Character(s) Product Reference Guide...
  • Page 128 Data Editing Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set Codabar Label ID Character(s) Set ABC Codabar Label ID Character(s) Set Code 11 Label ID Character(s) Set Standard 2 of 5 Label ID Character(s)
  • Page 129 Label ID Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set IATA Label ID Character(s) Set Concatinated ISBT 128 Label ID Character(s) Set MSI Label ID Character(s) Set Plessey Label ID Character(s)
  • Page 130 Data Editing Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See Label ID for full instructions. on page 107 ENTER/EXIT PROGRAMMING MODE Set Codablock F Label ID Character(s) Set Code 4 Label ID Character(s) Set Code 5 Label ID Character(s) Set Follett 2 of 5 Label ID Character(s)
  • Page 131: Case Conversion

    Case Conversion Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT Case Conversion = Disable (no case conversion)
  • Page 132 Data Editing conversion: BB22BB22. The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Scan the ENTER/EXIT barcode. 2.
  • Page 133: Chapter 12. Symbologies

    Chapter 12 Symbologies Introduction The reader supports the following symbologies (barcode types). Options for each sym- bology are included in this chapter. 1D Symbologies • • UPC-A Datalogic 2 of 5 • • UPC-E Codabar • • GTIN Formatting ABC Codabar •...
  • Page 134: Disable All Symbologies

    Symbologies Disable All Symbologies Scan this label to disable all symbologies. ENTER/EXIT PROGRAMMING MODE Disable all symbologies PowerScan PD7100 Corded...
  • Page 135: Coupon Control

    Coupon Control Coupon Control This feature is used to control the method of processing coupon labels. Options are: • Allow all — allow all coupon barcodes to be decoded • Enable only UPC/EAN — enables only UPC/EAN coupon decoding • Enable only GS1 DataBar —...
  • Page 136: Upc-A

    Symbologies UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. ENTER/EXIT PROGRAMMING MODE UPC-A = Disable DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data. ENTER/EXIT PROGRAMMING MODE UPC-A Check Character Transmission = Don’t Send DEFAULT...
  • Page 137: Expand Upc-A To Ean-13

    UPC-A UPC-A — cont. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. ENTER/EXIT PROGRAMMING MODE DEFAULT UPC-A to EAN-13 = Don’t Expand UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
  • Page 138: In-Store Minimum Reads

    Symbologies UPC-A — cont. In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read. In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'.
  • Page 139: Upc-E

    UPC-E UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. ENTER/EXIT PROGRAMMING MODE UPC-E = Disable DEFAULT UPC-E = Enable UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data. ENTER/EXIT PROGRAMMING MODE UPC-E Check Character Transmission = Don’t Send DEFAULT...
  • Page 140: Expand Upc-E To Ean-13

    Symbologies UPC-E — cont. Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. ENTER/EXIT PROGRAMMING MODE DEFAULT UPC-E to EAN-13 = Don’t Expand UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
  • Page 141: Upc-E Number System Character Transmission

    UPC-E UPC-E — cont. UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. ENTER/EXIT PROGRAMMING MODE UPC-E Number System Character = Do not transmit DEFAULT UPC-E Number System Character = Transmit Product Reference Guide...
  • Page 142: Upc-E Minimum Reads

    Symbologies UPC-E — cont. UPC-E Minimum Reads This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE UPC-E Minimum Reads = 1 DEFAULT UPC-E Minimum Reads = 2 UPC-E Minimum Reads = 3 UPC-E Minimum Reads = 4 PowerScan...
  • Page 143: Gtin Formatting

    GTIN Formatting GTIN Formatting This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conver- sion taking place, the addon information will be appended to the con- verted GTIN label.
  • Page 144: Ean 13

    Symbologies EAN 13 The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 barcodes. ENTER/EXIT PROGRAMMING MODE EAN 13 = Disable DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data.
  • Page 145: Ean-13 Flag 1 Character

    EAN 13 EAN 13 — cont. EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. ENTER/EXIT PROGRAMMING MODE EAN-13 Flag 1 Char= Don’t transmit DEFAULT EAN-13 Flag 1 Char= Transmit Product Reference Guide...
  • Page 146: Ean-13 Isbn Conversion

    Symbologies EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels. ENTER/EXIT PROGRAMMING MODE DEFAULT EAN-13 ISBN Conversion = Disable EAN-13 ISBN Conversion = Convert to ISBN ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.
  • Page 147: Ean 13 Minimum Reads

    EAN 13 EAN 13 — cont. EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT EAN 13 Minimum Reads = 1 EAN 13 Minimum Reads = 2 EAN 13 Minimum Reads = 3 EAN 13 Minimum Reads = 4...
  • Page 148: Ean 8

    Symbologies EAN 8 The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 barcodes. ENTER/EXIT PROGRAMMING MODE EAN 8 = Disable DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data.
  • Page 149: Expand Ean 8 To Ean 13

    EAN 8 EAN 8 — cont. Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. ENTER/EXIT PROGRAMMING MODE DEFAULT Expand EAN 8 to EAN 13 = Disable Expand EAN 8 to EAN 13 = Enable Product Reference Guide...
  • Page 150: Ean 8 Minimum Reads

    Symbologies EAN 8 — cont. EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT EAN 8 Minimum Reads = 1 EAN 8 Minimum Reads = 2 EAN 8 Minimum Reads = 3 EAN 8 Minimum Reads = 4...
  • Page 151: Upc/Ean Global Settings

    UPC/EAN Global Settings UPC/EAN Global Settings This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
  • Page 152 Symbologies UPC/EAN Global Settings — cont. UPC/EAN Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE UPC/EAN Decoding Level = 1 DEFAULT UPC/EAN Decoding Level = 2 UPC/EAN Decoding Level = 3 UPC/EAN Decoding Level = 4 UPC/EAN Decoding Level = 5 PowerScan PD7100 Corded...
  • Page 153: Upc/Ean Correlation

    UPC/EAN Global Settings UPC/EAN Global Settings — cont. UPC/EAN Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 154: Upc/Ean Price Weight Check

    Symbologies UPC/EAN Global Settings — cont. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits. Options are • Disabled • Enable 4-digit price-weight check-digit calculation • Enable 5-digit price-weight check-digit calculation • Enable European 4-digit price-weight check-digit calculation •...
  • Page 155: Upc-A Minimum Reads

    UPC/EAN Global Settings UPC/EAN Global Settings — cont. UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT UPC-A Minimum Reads = 1 UPC-A Minimum Reads = 2 UPC-A Minimum Reads = 3 UPC-A Minimum Reads = 4...
  • Page 156: Add-Ons

    Symbologies Add-Ons The following features apply to optional add-ons. Contact Customer Support for advanced programming of optional and conditional add-ons. NOTE Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): • • • GS1-128 If a UPC/EAN base label and a an add-on are both decoded, the reader will transmit the base label and add-on.
  • Page 157 Add-Ons Add-Ons — cont. Optional Add-ons — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-Ons = Enable P5 DEFAULT Optional Add-Ons = Disable GS1-128 Optional Add-Ons = Enable GS1-128 Product Reference Guide...
  • Page 158: Optional Add-On Timer

    Symbologies Add-Ons — cont. Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see Optional GS1-128 Add-On Timer on page 151 ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 10ms Optional Add-on Timer = 20ms...
  • Page 159 Add-Ons Add-Ons — cont. Optional Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 60ms DEFAULT Optional Add-on Timer = 70ms Optional Add-on Timer = 100ms Optional Add-on Timer = 120ms Optional Add-on Timer = 140ms Optional Add-on Timer = 160ms Product Reference Guide...
  • Page 160 Symbologies Add-Ons — cont. Optional Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional Add-on Timer = 180ms Optional Add-on Timer = 200ms Optional Add-on Timer = 220ms Optional Add-on Timer = 240ms Optional Add-on Timer = 260ms Optional Add-on Timer = 280ms Optional Add-on Timer = 300ms PowerScan PD7100 Corded...
  • Page 161: Optional Gs1-128 Add-On Timer

    Add-Ons Add-Ons — cont. Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of that type, see Optional Add-On Timer on page 148 ENTER/EXIT PROGRAMMING MODE DEFAULT Optional GS1-128 Add-On Timer = Disable...
  • Page 162 Symbologies Add-Ons — cont. Optional GS1-128 Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer = 60ms Optional GS1-128 Add-On Timer = 70ms Optional GS1-128 Add-On Timer = 100ms Optional GS1-128 Add-On Timer = 120ms Optional GS1-128 Add-On Timer = 140ms Optional GS1-128 Add-On Timer = 160ms PowerScan PD7100 Corded...
  • Page 163 Add-Ons Add-Ons — cont. Optional GS1-128 Add-On Timer — cont. ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer = 180ms Optional GS1-128 Add-On Timer = 200ms Optional GS1-128 Add-On Timer = 220ms Optional GS1-128 Add-On Timer = 240ms Optional GS1-128 Add-On Timer = 260ms Optional GS1-128 Add-On Timer = 280ms Optional GS1-128 Add-On Timer = 300ms Product Reference Guide...
  • Page 164: P2 Add-Ons Minimum Reads

    Symbologies Add-Ons — cont. P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label. ENTER/EXIT PROGRAMMING MODE P2 Add-Ons Minimum Reads = 1 DEFAULT P2 Add-Ons Minimum Reads = 2 P2 Add-Ons Minimum Reads = 3...
  • Page 165: P5 Add-Ons Minimum Reads

    Add-Ons Add-Ons — cont. P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label. ENTER/EXIT PROGRAMMING MODE DEFAULT P5 Add-Ons Minimum Reads = 1 P5 Add-Ons Minimum Reads = 2 P5 Add-Ons Minimum Reads = 3 P5 Add-Ons Minimum Reads = 4...
  • Page 166: Gs1-128 Add-Ons Minimum Reads

    Symbologies Add-Ons — cont. GS1-128 Add-Ons Minimum Reads This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base label. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1-128 Add-Ons Minimum Reads = 1 GS1-128 Add-Ons Minimum Reads = 2 GS1-128 Add-Ons Minimum Reads = 3 GS1-128 Add-Ons Minimum Reads = 4...
  • Page 167: Gs1 Databar Tm Omnidirectional

    GS1 DataBar Omnidirectional GS1 DataBar Omnidirectional The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology. GS1 DataBar Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar Omnidirectional barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Omnidirectional = Disable GS1 DataBar Omnidirectional = Enable GS1 DataBar Omnidirectional GS1-128 Emulation When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1-...
  • Page 168: Gs1 Databar Omnidirectional Minimum Reads

    Symbologies GS1 DataBar Omnidirectional — cont. GS1 DataBar Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omni- directional label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Omnidirectional Minimum Reads = 1 GS1 DataBar Omnidirectional Minimum Reads = 2 GS1 DataBar Omnidirectional Minimum Reads = 3...
  • Page 169: Gs1 Databar Tm Expanded

    GS1 DataBar Expanded GS1 DataBar Expanded The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology. GS1 DataBar Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar Expanded barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Expanded = Disable GS1 DataBar Expanded = Enable GS1 DataBar Expanded GS1-128 Emulation When enabled, GS1 DataBar Expanded barcodes will be translated to the GS1-128 label...
  • Page 170: Gs1 Databar Expanded Minimum Reads

    Symbologies GS1 DataBar Expanded — cont. GS1 DataBar Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Ex- panded label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Expanded Minimum Reads = 1 GS1 DataBar Expanded Minimum Reads = 2 GS1 DataBar Expanded Minimum Reads = 3...
  • Page 171: Gs1 Databar Expanded Length Control

    GS1 DataBar Expanded GS1 DataBar Expanded — cont. GS1 DataBar Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology. Variable Length — For variable-length decoding, a minimum length may be set. Fixed Length —...
  • Page 172: Gs1 Databar Expanded Set Length 1

    Symbologies GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar Expanded Length . Length 1 is the minimum label length if in Mode, or the first Control Variable Length fixed length if in Mode.
  • Page 173 GS1 DataBar Expanded GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT...
  • Page 174: Gs1 Databar Expanded Set Length 2

    Symbologies GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar Expanded Length . Length 2 is the maximum label length if in Mode, or the sec- Control Variable Length ond fixed length if in Mode.
  • Page 175 GS1 DataBar Expanded GS1 DataBar Expanded — cont. GS1 DataBar Expanded Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 74 = Length 2 is 74 Characters DEFAULT...
  • Page 176: Gs1 Databar Tm Limited

    Symbologies GS1 DataBar Limited The following options apply to the GS1 DataBar Limited (formerly RSS Limited) sym- bology. GS1 DataBar Limited Enable/Disable When disabled, the reader will not read GS1 DataBar Limited barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Limited = Disable GS1 DataBar Limited = Enable GS1 DataBar Limited GS1-128 Emulation When enabled, GS1 DataBar Limited barcodes will be translated to the GS1-128 label...
  • Page 177: Gs1 Databar Limited Minimum Reads

    GS1 DataBar Limited GS1 DataBar Limited — cont. GS1 DataBar Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Limited Minimum Reads = 1 GS1 DataBar Limited Minimum Reads = 2...
  • Page 178: Code 39

    Symbologies Code 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable When disabled, the reader will not read Code 39 barcodes. ENTER/EXIT PROGRAMMING MODE Code 39 = Disable DEFAULT Code 39 = Enable PowerScan PD7100 Corded...
  • Page 179: Code 39 Check Character Calculation

    Code 39 Code 39 — cont. Code 39 Check Character Calculation Enable this option to enable/disable calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data char- acter.
  • Page 180: Code 39 Check Character Transmission

    Symbologies Code 39 — cont. Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data. ENTER/EXIT PROGRAMMING MODE Code 39 Check Character Transmission = Don’t Send DEFAULT Code 39 Check Character Transmission = Send Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters.
  • Page 181: Code 39 Full Ascii

    Code 39 Code 39 — cont. Code 39 Full ASCII In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 39 Full ASCII = Disable Code 39 Full ASCII = Enable Product Reference Guide...
  • Page 182: Code 39 Quiet Zones

    Symbologies Code 39 — cont. Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
  • Page 183: Code 39 Minimum Reads

    Code 39 Code 39 — cont. Code 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 39 Minimum Reads = 1 Code 39 Minimum Reads = 2 Code 39 Minimum Reads = 3 Code 39 Minimum Reads = 4...
  • Page 184: Code 39 Decoding Level

    Symbologies Code 39 — cont. Code 39 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 185 Code 39 Code 39 — cont. Code 39 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Decoding Level = 1 Code 39 Decoding Level = 2 DEFAULT Code 39 Decoding Level = 3 Code 39 Decoding Level = 4 Code 39 Decoding Level = 5 Product Reference Guide...
  • Page 186: Code 39 Length Control

    Symbologies Code 39 — cont. Code 39 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set. Fixed Length —...
  • Page 187: Code 39 Set Length 1

    Code 39 Code 39 — cont. Code 39 Set Length 1 This feature specifies one of the barcode lengths for . Length 1 Code 39 Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 188 Symbologies Code 39 — cont. Code 39 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 02 = Length 1 is 2 Characters DEFAULT...
  • Page 189: Code 39 Set Length 2

    Code 39 Code 39 — cont. Code 39 Set Length 2 This feature specifies one of the barcode lengths for . Length 2 Code 39 Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode.
  • Page 190 Symbologies Code 39 — cont. Code 39 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 191: Code 39 Interdigit Ratio

    Code 39 Code 39 — cont. Code 39 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = Disable Code 39 Interdigit Ratio = 1 Code 39 Interdigit Ratio = 2 Code 39 Interdigit Ratio = 3 DEFAULT...
  • Page 192 Symbologies Code 39 — cont. Code 39 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Interdigit Ratio = 8 Code 39 Interdigit Ratio = 9 Code 39 Interdigit Ratio = 10 PowerScan PD7100 Corded...
  • Page 193: Code 39 Character Correlation

    Code 39 Code 39 — cont. Code 39 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 194: Code 39 Stitching

    Symbologies Code 39 Stitching This option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar- code are presented to the reader with this feature enabled, the barcode parts will be as- sembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
  • Page 195: Code 32 (Italian Pharmaceutical)

    Code 32 (Italian Pharmaceutical) Code 32 (Italian Pharmaceutical) The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 32 = Disable Code 32 = Enable Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings:...
  • Page 196: Code 32 Check Character Transmission

    Symbologies Code 32 (Italian Pharmaceutical) — cont. Code 32 Check Character Transmission Enable this option to transmit the check character along with Code 32 barcode data. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 32 Check Character Transmission = Don’t Send Code 32 Check Character Transmission = Send Code 32 Start/Stop Character Transmission This option enables/disable transmission of Code 32 start and stop characters.
  • Page 197: Code 39 Cip (French Pharmaceutical)

    Code 39 CIP (French Pharmaceutical) Code 39 CIP (French Pharmaceutical) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 39 CIP = Disable Code 39 CIP = Enable Code 128 The following options apply to the Code 128 symbology.
  • Page 198: Expand Code 128 To Code 39

    Symbologies Code 128 — cont. Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 to Code 39 = Don’t Expand Code 128 to Code 39 = Expand Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data.
  • Page 199: Code 128 Function Character Transmission

    Code 128 Code 128 — cont. Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 Function Character Transmission = Don’t Send Code 128 Function Character Transmission = Send Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange”...
  • Page 200: Code 128 Quiet Zones

    Symbologies Code 128 — cont. Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
  • Page 201: Code 128 Minimum Reads

    Code 128 Code 128 — cont. Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 128 Minimum Reads = 1 Code 128 Minimum Reads = 2 Code 128 Minimum Reads = 3 Code 128 Minimum Reads = 4...
  • Page 202: Code 128 Decoding Level

    Symbologies Code 128 — cont. Code 128 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 203 Code 128 Code 128 — cont. Code 128 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 128 Decoding Level = 1 Code 128 Decoding Level = 2 DEFAULT Code 128 Decoding Level = 3 Code 128 Decoding Level = 4 Code 128 Decoding Level = 5 Product Reference Guide...
  • Page 204: Code 128 Length Control

    Symbologies Code 128 — cont. Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set. Fixed Length —...
  • Page 205: Code 128 Set Length 1

    Code 128 Code 128 — cont. Code 128 Set Length 1 This feature specifies one of the barcode lengths for . Length Code 128 Length Control 1 is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 206 Symbologies Code 128 — cont. Code 128 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT...
  • Page 207: Code 128 Set Length 2

    Code 128 Code 128 — cont. Code 128 Set Length 2 This feature specifies one of the barcode lengths for . Length Code 128 Length Control 2 is the maximum label length if in Mode, or the second fixed length if Variable Length Mode.
  • Page 208 Symbologies Code 128 — cont. Code 128 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 128 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 80 = Length 2 is 80 Characters DEFAULT...
  • Page 209: Code 128 Character Correlation

    Code 128 Code 128 — cont. Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 210: Code 128 Stitching

    Symbologies Code 128 — cont. Code 128 Stitching This option enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
  • Page 211: Gs1-128

    GS1-128 GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128, EAN 128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format.
  • Page 212: Interleaved 2 Of 5 (I 2 Of 5)

    Symbologies Interleaved 2 of 5 (I 2 of 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT I 2 of 5 = Disable I 2 of 5 = Enable...
  • Page 213: I 2 Of 5 Check Character Calculation

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE DEFAULT I 2 of 5 Check Character Calculation = Disable...
  • Page 214: I 2 Of 5 Check Character Transmission

    Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation — cont. ENTER/EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation = Check Italian Post I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data.
  • Page 215: I 2 Of 5 Minimum Reads

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read..
  • Page 216: Of 5 Decoding Level

    Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and Standard 2 of 5. NOTE Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
  • Page 217 Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE 2 of 5 Decoding Level = 1 2 of 5 Decoding Level = 2 DEFAULT 2 of 5 Decoding Level = 3 2 of 5 Decoding Level = 4...
  • Page 218: I 2 Of 5 Length Control

    Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
  • Page 219: I 2 Of 5 Set Length 1

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for . Length 1 is I 2 of 5 Length Control the minimum label length if in Mode, or the first fixed length if in Variable Length...
  • Page 220 Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 221: I 2 Of 5 Set Length 2

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for . Length 2 is I 2 of 5 Length Control the maximum label length if in Mode, or the second fixed length if in Variable Length...
  • Page 222 Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 223: I 2 Of 5 Character Correlation

    Interleaved 2 of 5 (I 2 of 5) Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
  • Page 224: I 2 Of 5 Stitching

    Symbologies Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Stitching This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing require- ments are met.
  • Page 225: Interleaved 2 Of 5 Cip Hr

    Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 = Disable...
  • Page 226: Datalogic 2 Of 5 Check Character Calculation

    Symbologies Datalogic 2 of 5 — cont. Datalogic 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 Check Character Calculation = Disable...
  • Page 227: Datalogic 2 Of 5 Minimum Reads

    Datalogic 2 of 5 — cont. Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 la- bel must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE...
  • Page 228: Datalogic 2 Of 5 Length Control

    Fixed Length — For fixed length decoding, two different lengths may be set. ENTER/EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 Length Control = Variable Length Datalogic 2 of 5 Length Control = Fixed Length PowerScan PD7100 Corded...
  • Page 229: Datalogic 2 Of 5 Set Length 1

    6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program- ming Mode. This completes the procedure. See for some examples of how to set this feature. Table 27 Table 27. Datalogic 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES Desired Setting...
  • Page 230 Symbologies Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
  • Page 231: Datalogic 2 Of 5 Set Length 2

    05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program- ming Mode. 4. Scan the barcode: SELECT Datalogic 2 of 5 LENGTH 2 SETTING. 5. Scan the appropriate two digits from the keypad in , that rep- Appendix E, Keypad resent the length setting which was determined in the steps above.
  • Page 232 Symbologies Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
  • Page 233: Datalogic 2 Of 5 Interdigit Maximum Ratio

    This feature specifies the maximum ratio between intercharacter space and module for Datalogic 2 of 5. ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Interdigit Maximum Ratio = Disable Datalogic 2 of 5 Interdigit Maximum Ratio = 1 Datalogic 2 of 5 Interdigit Maximum Ratio = 2...
  • Page 234 Symbologies Datalogic 2 of 5 Interdigit Maximum Ratio — cont. Datalogic 2 of 5 Interdigit Maximum Ratio = 6 Datalogic 2 of 5 Interdigit Maximum Ratio = 7 Datalogic 2 of 5 Interdigit Maximum Ratio = 8 Datalogic 2 of 5 Interdigit Maximum Ratio = 9...
  • Page 235: Datalogic 2 Of 5 Character Correlation

    Datalogic 2 of 5 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
  • Page 236: Datalogic 2 Of 5 Stitching

    Datalogic 2 of 5 — cont. Datalogic 2 of 5 Stitching This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Data- logic 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all bar-...
  • Page 237: Codabar

    Codabar Codabar The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar = Disable Codabar = Enable Product Reference Guide...
  • Page 238: Codabar Check Character Calculation

    Symbologies Codabar — cont. Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check character in the label is treated as a data character ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Check Character Calculation = Don’t Calculate Codabar Check Character Calculation = Enable AIM standard check char.
  • Page 239: Codabar Check Character Transmission

    Codabar Codabar — cont. Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data. ENTER/EXIT PROGRAMMING MODE Codabar Check Character Transmission = Don’t Send DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
  • Page 240: Codabar Start/Stop Character Set

    Symbologies Codabar — cont. Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters. ENTER/EXIT PROGRAMMING MODE Codabar Check Character Set = ABCD/TN*E Codabar Check Character Set = ABCD/ABCD Codabar Check Character Set = abcd/tn*e DEFAULT Codabar Check Character Set = abcd/abcd PowerScan PD7100 Corded...
  • Page 241: Codabar Start/Stop Character Match

    Codabar Codabar — cont. Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Start/Stop Character Match = Don’t Require Match Codabar Start/Stop Character Match = Require Match Product Reference Guide...
  • Page 242: Codabar Quiet Zones

    Symbologies Codabar — cont. Codabar Quiet Zones This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
  • Page 243: Codabar Minimum Reads

    Codabar Codabar — cont. Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT Codabar Minimum Reads = 1 Codabar Minimum Reads = 2 Codabar Minimum Reads = 3 Codabar Minimum Reads = 4 Product Reference Guide...
  • Page 244: Codabar Decoding Level

    Symbologies Codabar — cont. Codabar Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 245 Codabar Codabar — cont. Codabar Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level = 1 Codabar Decoding Level = 2 DEFAULT Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 Product Reference Guide...
  • Page 246: Codabar Length Control

    Symbologies Codabar — cont. Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set. Fixed Length — For fixed length decoding, two different lengths may be set.
  • Page 247: Codabar Set Length 1

    Codabar Codabar — cont. Codabar Set Length 1 This feature specifies one of the barcode lengths for . Length 1 Codabar Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 248 Symbologies Codabar — cont. Codabar Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 03 = Length 1 is 3 Characters DEFAULT...
  • Page 249: Codabar Set Length 2

    Codabar Codabar — cont. Codabar Set Length 2 This feature specifies one of the barcode lengths for . Length 2 Codabar Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode. The length includes the barcode’s start, stop, check and data Fixed Length characters.
  • Page 250 Symbologies Codabar — cont. Codabar Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select CodabarLength 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 251: Codabar Interdigit Ratio

    Codabar Codabar — cont. Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = Disable Codabar Interdigit Ratio = 1 Codabar Interdigit Ratio = 2 Codabar Interdigit Ratio = 3 DEFAULT Codabar Interdigit Ratio = 4 Codabar Interdigit Ratio = 5...
  • Page 252 Symbologies Codabar — cont. Codabar Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = 6 Codabar Interdigit Ratio = 7 Codabar Interdigit Ratio = 8 Codabar Interdigit Ratio = 9 Codabar Interdigit Ratio = 10 PowerScan PD7100 Corded...
  • Page 253: Codabar Character Correlation

    Codabar Codabar — cont. Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 254: Codabar Stitching

    Symbologies Codabar Stitching This option enables/disables stitching for Codabar labels. When parts of a Codabar bar- code are presented to the reader with this feature enabled, the barcode parts will be as- sembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
  • Page 255: Abc Codabar

    ABC Codabar ABC Codabar The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. ENTER/EXIT PROGRAMMING MODE DEFAULT ABC Codabar = Disable ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
  • Page 256: Abc Codabar Dynamic Concatenation Timeout

    Symbologies ABC Codabar — cont. ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Con- catenation Mode. ENTER/EXIT PROGRAMMING MODE ABC Codabar Dynamic Concatenation Timeout = 50 msec ABC Codabar Dynamic Concatenation Timeout = 100 msec DEFAULT ABC Codabar Dynamic Concatenation Timeout = 200 msec ABC Codabar Dynamic Concatenation Timeout = 500 msec...
  • Page 257: Abc Codabar Force Concatenation

    ABC Codabar ABC Codabar — cont. ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated. ENTER/EXIT PROGRAMMING MODE DEFAULT ABC Codabar Force Concatenation = Disable ABC Codabar Force Concatenation = Enable Product Reference Guide...
  • Page 258: Code 11

    Symbologies Code 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 11 = Disable Code 11 = Enable PowerScan PD7100 Corded...
  • Page 259: Code 11 Check Character Calculation

    Code 11 Code 11 — cont. Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check char- acter. ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Calculation = Disable Code 11 Check Character Calculation = Check C Code 11 Check Character Calculation = Check K DEFAULT Code 11 Check Character Calculation = Check C and K...
  • Page 260: Code 11 Check Character Transmission

    Symbologies Code 11 — cont. Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Transmission = Don’t Send DEFAULT Code 11 Check Character Transmission = Send PowerScan PD7100 Corded...
  • Page 261: Code 11 Minimum Reads

    Code 11 Code 11 — cont. Code 11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 11 Minimum Reads = 1 Code 11 Minimum Reads = 2 Code 11 Minimum Reads = 3 Code 11 Minimum Reads = 4...
  • Page 262: Code 11 Length Control

    Symbologies Code 11 — cont. Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set. Fixed Length —...
  • Page 263: Code 11 Set Length 1

    Code 11 Code 11 — cont. Code 11 Set Length 1 This feature specifies one of the barcode lengths for . Length 1 Code 11 Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 264 Symbologies Code 11 — cont. Code 11 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 04 = Length 1 is 4 Characters DEFAULT...
  • Page 265: Code 11 Set Length 2

    Code 11 Code 11 — cont. Code 11 Set Length 2 This feature specifies one of the barcode lengths for . Length 2 Code 11 Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode.
  • Page 266 Symbologies Code 11 — cont. Code 11 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 267: Code 11 Interdigit Ratio

    Code 11 Code 11 — cont. Code 11 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels. ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = Disable Code 11 Interdigit Ratio = 1 Code 11 Interdigit Ratio = 2 Code11 Interdigit Ratio = 3 DEFAULT...
  • Page 268 Symbologies Code 11 — cont. Code 11 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = 6 Code 11 Interdigit Ratio = 7 Code 11 Interdigit Ratio = 8 Code 11 Interdigit Ratio = 9 Code 11 Interdigit Ratio = 10 PowerScan PD7100 Corded...
  • Page 269: Code 11 Decoding Level

    Code 11 Code 11 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 270 Symbologies Code 11 — cont. Code 11 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level = 1 Codabar Decoding Level = 2 DEFAULT Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 PowerScan PD7100 Corded...
  • Page 271: Code 11 Character Correlation

    Code 11 Code 11 — cont. Code 11 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
  • Page 272: Code 11 Stitching

    Symbologies Code 11 Stitching This option enables/disables stitching for Code 11 labels. When parts of a Code 11 bar- code are presented to the reader with this feature enabled, the barcode parts will be as- sembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
  • Page 273: Standard 2 Of 5

    Standard 2 of 5 Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 = Disable Standard 2 of 5 = Enable Product Reference Guide...
  • Page 274: Standard 2 Of 5 Check Character Calculation

    Symbologies Standard 2 of 5 — cont. Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 Check Character Calculation = Disable Standard 2 of 5 Check Character Calculation = Enable Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character.
  • Page 275: Standard 2 Of 5 Minimum Reads

    Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 Minimum Reads = 1...
  • Page 276: Standard 2 Of 5 Length Control

    Symbologies Standard 2 of 5 — cont. Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
  • Page 277: Standard 2 Of 5 Set Length 1

    Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control Length 1 is the minimum label length if in Mode, or the first fixed Variable Length length if in...
  • Page 278 Symbologies Standard 2 of 5 — cont. Standard 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 08 = Length 1 is 8 Characters DEFAULT...
  • Page 279: Standard 2 Of 5 Set Length 2

    Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control Length 2 is the maximum label length if in Mode, or the second fixed Variable Length length if in...
  • Page 280 Symbologies Standard 2 of 5 — cont. Standard 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 281: Standard 2 Of 5 Character Correlation

    Standard 2 of 5 Standard 2 of 5 — cont. Standard 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids.
  • Page 282: Standard 2 Of 5 Stitching

    Symbologies Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Stan- dard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all bar- code proofing requirements are met.
  • Page 283: Industrial 2 Of 5

    Industrial 2 of 5 Industrial 2 of 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Industrial 2 of 5 = Disable Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check char-...
  • Page 284: Industrial 2 Of 5 Check Character Transmission

    Symbologies Industrial 2 of 5 — cont. Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Check Character Transmission = Disable DEFAULT Industrial 2 of 5 Check Character Transmission = Enable PowerScan PD7100 Corded...
  • Page 285: Industrial 2 Of 5 Length Control

    Industrial 2 of 5 Industrial 2 of 5 — cont. Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the In- dustrial 2 of 5 symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set.
  • Page 286: Industrial 2 Of 5 Set Length 1

    Symbologies Industrial 2 of 5 — cont. Industrial 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control Length 1 is the minimum label length if in Mode, or the first fixed Variable Length length if in Mode.
  • Page 287 Industrial 2 of 5 Industrial 2 of 5 — cont. Industrial 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Industrial 2 of 5 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 288: Industrial 2 Of 5 Set Length 2

    Symbologies Industrial 2 of 5 — cont. Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control Length 2 is the maximum label length if in Mode, or the second fixed Variable Length length if in Mode.
  • Page 289 Industrial 2 of 5 Industrial 2 of 5 — cont. Industrial 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Industrial 2 of5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
  • Page 290: Industrial 2 Of 5 Minimum Reads

    Symbologies Industrial 2 of 5 — cont. Industrial 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Industrial 2 of 5 la- bel must be decoded before it is accepted as good read.. ENTER/EXIT PROGRAMMING MODE DEFAULT Industrial 2 of 5 Minimum Reads = 1 Industrial 2 of 5 Minimum Reads = 2...
  • Page 291: Industrial 2 Of 5 Stitching

    Industrial 2 of 5 Industrial 2 of 5 — cont. Industrial 2 of 5 Stitching Enables/disables fixed length stitching for Industrial 2 of 5. ENTER/EXIT PROGRAMMING MODE DEFAULT Industrial 2 of 5 Stitching = Disable Industrial 2 of 5 Stitching = Enable Industrial 2 of 5 Character Correlation Enable/disables character correlation for Industrial 2 of 5.
  • Page 292: Iata

    Symbologies IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. ENTER/EXIT PROGRAMMING MODE DEFAULT IATA = Disable IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check char- acter.
  • Page 293: Isbt 128

    ISBT 128 ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT ISBN 128 Concatenation = Disable ISBN 128 Concatenation = Enable Product Reference Guide...
  • Page 294: Isbt 128 Concatenation Mode

    Symbologies ISBT 128 — cont. ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. ISBT 128 Concatenation see page This option is only valid when is enabled ( NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT ISBT 128 Concatenation Mode = Static ISBT 128 Concatenation Mode = Dynamic PowerScan PD7100 Corded...
  • Page 295: Isbt 128 Dynamic Concatenation Timeout

    ISBT 128 ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode. ENTER/EXIT PROGRAMMING MODE ISBT 128 Dynamic Concatenation Timeout = 50 msec ISBT 128 Dynamic Concatenation Timeout = 100 msec DEFAULT ISBT 128 Dynamic Concatenation Timeout = 200 msec ISBT 128 Dynamic Concatenation Timeout = 500 msec ISBT 128 Dynamic Concatenation Timeout = 750 msec ISBT 128 Dynamic Concatenation Timeout = 1 second...
  • Page 296: Isbt 128 Force Concatenation

    DEFAULT ISBT 128 Force Concatenation = Disable ISBT 128 Force Concatenation = Enable ISBT 128 Advanced Concatenation Options Use the Datalogic Aladdin Configuration Application or contact Cus- tomer Support to set up pairs of label types for concatenation. NOTE PowerScan...
  • Page 297: Msi

    The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels. ENTER/EXIT PROGRAMMING MODE DEFAULT MSI = Disable MSI = Enable Product Reference Guide...
  • Page 298: Msi Check Character Calculation

    Symbologies MSI — cont. MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character. ENTER/EXIT PROGRAMMING MODE MSI Check Character Calculation = Disable DEFAULT MSI Check Character Calculation = Enable Mod10 MSI Check Character Calculation = Enable Mod11/10 MSI Check Character Calculation = Enable Mod10/10 PowerScan PD7100 Corded...
  • Page 299: Msi Check Character Transmission

    MSI — cont. MSI Check Character Transmission Enables/disables transmission of an MSI check character. ENTER/EXIT PROGRAMMING MODE MSI Check Character Transmission = Disable DEFAULT MSI Check Character Transmission = Enable MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology.
  • Page 300: Msi Set Length 1

    Symbologies MSI — cont. MSI Set Length 1 This feature specifies one of the barcode lengths for . Length 1 is the MSI Length Control minimum label length if in Mode, or the first fixed length if in Variable Length Fixed Mode.
  • Page 301 MSI — cont. MSI Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select MSI Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT...
  • Page 302: Msi Set Length 2

    Symbologies MSI — cont. MSI Set Length 2 This feature specifies one of the barcode lengths for . Length 2 is the MSI Length Control maximum label length if in Mode, or the second fixed length if in Variable Length Fixed Mode.
  • Page 303 MSI — cont. MSI Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select MSI Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 304: Msi Minimum Reads

    Symbologies MSI — cont. MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE MSI Minimum Reads = 1 MSI Minimum Reads = 2 MSI Minimum Reads = 3 DEFAULT MSI Minimum Reads = 4...
  • Page 305: Msi Decoding Level

    MSI — cont. MSI Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 306 Symbologies MSI — cont. MSI Decoding Level — cont. DEFAULT MSI Decoding Level = 3 MSI Decoding Level = 4 MSI Decoding Level = 5 PowerScan PD7100 Corded...
  • Page 307: Plessey

    Plessey Plessey The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Plessey = Disable Plessey = Enable Product Reference Guide...
  • Page 308: Plessey Check Character Calculation

    Symbologies Plessey — cont. Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character. ENTER/EXIT PROGRAMMING MODE Plessey Check Character Calculation = Disable DEFAULT Plessey Check Character Calculation = Enable Plessey std. check char. verification Plessey Check Character Calculation = Enable Anker check char.
  • Page 309: Plessey Check Character Transmission

    Plessey Plessey — cont. Plessey Check Character Transmission Enables/disables transmission of an MSI check character. ENTER/EXIT PROGRAMMING MODE Plessey Check Character Transmission = Disable DEFAULT Plessey Check Character Transmission = Enable PLessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology.
  • Page 310: Plessey Set Length 1

    Symbologies Plessey — cont. Plessey Set Length 1 This feature specifies one of the barcode lengths for . Length 1 PLessey Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 311 Plessey Plessey — cont. Plessey Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Plessey Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT...
  • Page 312: Plessey Set Length 2

    Symbologies Plessey — cont. Plessey Set Length 2 This feature specifies one of the barcode lengths for . Length 2 PLessey Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode. Length includes the barcode’s check, data, and full-ASCII shift Fixed Length characters.
  • Page 313 Plessey Plessey — cont. Plessey Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Plessey Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 314: Plessey Minimum Reads

    Symbologies Plessey — cont. Plessey Minimum Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE Plessey Minimum Reads = 1 Plessey Minimum Reads = 2 Plessey Minimum Reads = 3 DEFAULT Plessey Minimum Reads = 4...
  • Page 315: Plessey Decoding Level

    Plessey Plessey — cont. Plessey Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 316: Plessey Stitching

    Symbologies Plessey — cont. Plessey Decoding Level — cont. DEFAULT Plessey Decoding Level = 3 Plessey Decoding Level = 4 Plessey Decoding Level = 5 Plessey Stitching Enables/disables fixed length stitching for Plessey. ENTER/EXIT PROGRAMMING MODE DEFAULT Plessey Stitching = Disable Plessey Stitching = Enable PowerScan PD7100 Corded...
  • Page 317: Plessey Character Correlation

    Code 93 Plessey — cont. Plessey Character Correlation Enables/disables Character Correlation for Plessey. ENTER/EXIT PROGRAMMING MODE DEFAULT Plessey Character Correlation = Disable Plessey Character Correlation = Enable Code 93 The following options apply to the Code 93 symbology. Code 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels.
  • Page 318: Code 93 Check Character Calculation

    Symbologies Code 93 — cont. Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character. ENTER/EXIT PROGRAMMING MODE Code 93 Check Character Calculation = Disable Code 93 Check Character Calculation = Enable Check C Code 93 Check Character Calculation = Enable Check K DEFAULT Code 93 Check Character Calculation = Enable Check C and K...
  • Page 319: Code 93 Check Character Transmission

    Code 93 Code 93 — cont. Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character. ENTER/EXIT PROGRAMMING MODE Code 93 Check Character Transmission = Disable DEFAULT Code 93 Check Character Transmission = Enable Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology.
  • Page 320: Code 93 Set Length 1

    Symbologies Code 93 — cont. Code 93 Set Length 1 This feature specifies one of the barcode lengths for . Length 1 Code 93 Length Control is the minimum label length if in Mode, or the first fixed length if in Variable Length Mode.
  • Page 321 Code 93 Code 93 — cont. Code 93 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 93 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT...
  • Page 322: Code 93 Set Length 2

    Symbologies Code 93 — cont. Code 93 Set Length 2 This feature specifies one of the barcode lengths for . Length 2 Code 93 Length Control is the maximum label length if in Mode, or the second fixed length if Variable Length Mode.
  • Page 323 Code 93 Code 93 — cont. Code 93 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 93 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT...
  • Page 324: Code 93 Minimum Reads

    Symbologies Code 93 — cont. Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 93 Minimum Reads = 1 Code 93 Minimum Reads = 2 Code 93 Minimum Reads = 3 Code 93 Minimum Reads = 4...
  • Page 325: Code 93 Decoding Level

    Code 93 Code 93 — cont. Code 93 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
  • Page 326 Symbologies Code 93 — cont. Code 93 Decoding Level — cont. DEFAULT Code 93 Decoding Level = 3 Code 93 Decoding Level = 4 Code 93 Decoding Level = 5 PowerScan PD7100 Corded...
  • Page 327: Code 93 Quiet Zones

    Code 93 Code 93 — cont. Code 93 Quiet Zones Enables/disables fixed length stitching for Code 93. ENTER/EXIT PROGRAMMING MODE Code 93 Quiet Zones = No Quiet Zones Code 93 Quiet Zones = Quiet Zone on one side Code 93 Quiet Zones = Quiet Zones on two sides DEFAULT Code 93 Quiet Zones = Auto Code 93 Quiet Zones = Virtual Quiet Zones on two sides...
  • Page 328: Code 93 Stitching

    Symbologies Code 93 — cont. Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93. ENTER/EXIT PROGRAMMING MODE Code 93 Stitching = Disable DEFAULT Code 93 Stitching = Enable Code 93 Character Correlation Enables/disables Character Correlation for Code 93. ENTER/EXIT PROGRAMMING MODE Code 93 Character Correlation = Disable DEFAULT...
  • Page 329: Codablock F

    Codablock F Codablock F The following options apply to the Codablock F symbology. Codablock F Enable/Disable Enables/Disables the ability of the imager to decode Codablock F labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Codablock F = Disable Codablock F = Enable Product Reference Guide...
  • Page 330: Codablock F Ean Enable/Disable

    Symbologies Codablock F — cont. Codablock F EAN Enable/Disable Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position). ENTER/EXIT PROGRAMMING MODE DEFAULT Codablock F EAN = Disable Codablock F EAN = Enable Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not.
  • Page 331: Codablock F Length Control

    Codablock F Codablock F — cont. Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology. Variable Length — For variable length decoding, a minimum and maximum length may be set. Fixed Length —...
  • Page 332: Codablock F Set Length 1

    Symbologies Codablock F — cont. Codablock F Set Length 1 This feature specifies one of the barcode lengths for Codablock F Length Control Length 1 is the minimum label length if in Mode, or the first fixed Variable Length length if in Mode.
  • Page 333 Codablock F Codablock F — cont. Codablock F Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Codablock F Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 003 = Length 1 is 3 Characters DEFAULT...
  • Page 334: Codablock F Set Length 2

    Symbologies Codablock F — cont. Codablock F Set Length 2 This feature specifies one of the barcode lengths for Codablock F Length Control Length 2 is the maximum label length if in Mode, or the second fixed Variable Length length if in Mode.
  • Page 335 Codablock F Codablock F — cont. Codablock F Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Codablock F Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL 100 = Length 2 is 100 Characters DEFAULT...
  • Page 336: Code 4

    Symbologies Code 4 The following options apply to the Code 4 symbology. Code 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 4 = Disable Code 4 = Enable PowerScan PD7100 Corded...
  • Page 337: Code 4 Check Character Transmission

    Code 4 Code 4 — cont. Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character. ENTER/EXIT PROGRAMMING MODE Code 4 Check Character Transmission = Don’t Send DEFAULT Code 4 Check Character Transmission = Send Code 4 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label da- ENTER/EXIT PROGRAMMING MODE...
  • Page 338: Code 5

    Symbologies Code 5 The following options apply to the Code 5 symbology. Code 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 5 = Disable Code 5 = Enable PowerScan PD7100 Corded...
  • Page 339: Code 5 Check Character Transmission

    Code 5 Code 5 — cont. Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character. ENTER/EXIT PROGRAMMING MODE Code 5 Check Character Transmission = Don’t Send DEFAULT Code 5 Check Character Transmission = Send Code 5 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label da- ENTER/EXIT PROGRAMMING MODE...
  • Page 340: Code 4 And Code 5 Common Configuration Items

    Symbologies Code 4 and Code 5 Common Configuration Items The following options apply to both Code 4 and Code 5 symbologies. Code 4 and 5 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
  • Page 341 Code 4 and Code 5 Common Configuration Items Code 4 and Code 5 Common Configuration Items — cont. Code 4 and 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 4 and Code 5 Decoding Level = 1 Code 4 and Code 5 Decoding Level = 2 DEFAULT Code 4 and Code 5 Decoding Level = 3 Code 4 and Code 5 Decoding Level = 4...
  • Page 342: Code 4 And Code 5 Minimum Reads

    Symbologies Code 4 and Code 5 Common Configuration Items — cont. Code 4 and Code 5 Minimum Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE DEFAULT Code 4 or Code 5 Minimum Reads = 1...
  • Page 343: Follett 2 Of 5

    Follett 2 of 5 Follett 2 of 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels. ENTER/EXIT PROGRAMMING MODE DEFAULT Follett 2 of 5 = Disable Follett 2 of 5 = Enable Product Reference Guide...
  • Page 344 Symbologies NOTES PowerScan PD7100 Corded...
  • Page 345: Appendix A. Technical Specifications

    Appendix A Technical Specifications Table 45 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 46 provides Standard Cable Pinouts. Table 45. Technical Specifications Item Description Physical Characteristics Yellow/Black Color Black/Black Height 7.5”/190 mm Dimensions Length 4.5”/115 mm Width 3.0”/75 mm Weight (without cable) Approximately 9.9 ounces/280 g (without cable)
  • Page 346 Item Description Minimum Element Width 3 mil Print Contrast Minimum 15% minimum reflectance UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Code 32; Code 128; Code 128 ISBT; Code 128 add-ons; I 2 of 5; Standard 2 of 5; Code 11; Decode Capability Codabar;...
  • Page 347: Standard Cable Pinouts

    Standard Cable Pinouts Standard Cable Pinouts Figure 7 Table 46 provide standard pinout information for the Base Station’s in- terface cable. Figure 7. Standard Cable Pinouts Bottom of Scanner Cable Cable Strain Relief Interface Cable Port Pin 1 Pin 10 To Host Cable Clip (Latch) The signal descriptions in...
  • Page 348 NOTES PowerScan PD7100 Corded...
  • Page 349: Appendix B. Standard Defaults

    Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of Table 47 The settings in this table are as applied to a standard RS-232 interface. See Table 48 a listing of default exceptions to this list as appled to other interface types. Page references are also provided for feature descriptions and programming barcodes for each parameter.
  • Page 350 Parameter Default Your Setting Page Number Start scanning imme- Laser Pointer Control diately after trigger Laser Pointer Period 500 ms Green Spot Duration 300 ms RS-232 Baud Rate 9600 Data Bits 8 Data Bits Stop Bits 1 Stop Bit Parity None Handshaking Control Disable...
  • Page 351 Parameter Default Your Setting Page Number USB Keyboard Speed 1 ms USB-OEM USB-OEM Device Usage Handheld Scanner USB-OEM Interface Options Ignore IBM 46XX 46xx Number of Host Resets 6 Host Resets Transmit Labels in Code 39 Format IBM Std Format IBM 46XX Interface Options Ignore Wand Emulation...
  • Page 352 Parameter Default Your Setting Page Number In-Store Minimum Reads UPC-E UPC-E Enable/Disable Enable UPC-E Check Character Transmission Send Expand UPC-E to EAN-13 Don’t Expand Expand UPC-E to UPC-A Don’t Expand UPC-E Number System Character Trans- Transmit mission UPC-E Minimum Reads GTIN Disable GTIN Formatting...
  • Page 353 Parameter Default Your Setting Page Number Disable P2, P5 and Optional Add-ons Optional Add-On Timer 70 ms Optional GS1-128 Add-On Timer Disable P2 Add-Ons Minimum Reads P5 Add-Ons Minimum Reads GS1-128 Add-Ons Minimum Reads GS1 DataBar Omnidirectional GS1 DataBar Omnidirectional Enable/ Disable Disable GS1 DataBar Omnidirectional GS1-128...
  • Page 354 Parameter Default Your Setting Page Number Code 39 Full ASCII Disable Code 39 Quiet Zones Auto Code 39 Minimum Reads Code 39 Decoding Level Code 39 Length Control Variable Code 39 Set Length 1 Code 39 Set Length 2 Code 39 Interdigit Ratio Code 39 Character Correlation Disable Code 39 Stitching...
  • Page 355 Interleaved 2 of 5 CIP HR Enable/Disable Disable Datalogic 2 of 5 Datalogic 2 of 5 Enable/Disable Enable Datalogic 2 of 5 Check Character Calcu- Disable lation Datalogic 2 of 5 Minimum Reads Datalogic 2 of 5 Length Control Variable...
  • Page 356 Parameter Default Your Setting Page Number Codabar Check Character Transmission Send Codabar Start/Stop Character Transmis- Transmit sion Codabar Start/Stop Character Set abcd/abcd Codabar Start/Stop Character Match Don’t Require Match Codabar Quiet Zones Auto Codabar Minimum Reads Codabar Decoding Level Codabar Length Control Variable Codabar Set Length 1 Codabar Set Length 2...
  • Page 357 Parameter Default Your Setting Page Number Code 11 Stitching Disable Standard 2 of 5 Standard 2 of 5 Enable/Disable Disable Standard 2 of 5 Check Character Calcu- Disable lation Standard 2 of 5 Check Character Trans- Send mission Standard 2 of 5 Minimum Reads Standard 2 of 5 Decoding Level Standard 2 of 5 Length Control Variable...
  • Page 358 Parameter Default Your Setting Page Number ISBT 128 Concatenation Mode Static ISBT 128 Dynamic Concatenation Time- 200 ms ISBT 128 Force Concatenation Disable ISBT 128 Advanced Concatenation Disable Options MSI Enable/Disable Disable MSI Check Character Calculation Enable Mod 10 MSI Check Character Transmission Enable MSI Length Control Variable...
  • Page 359 Parameter Default Your Setting Page Number Code 93 Check Character Calculation Enable Check C & K Code 93 Check Character Transmission Enable Code 93 Length Control Variable Code 93 Set Length 1 1 Char Code 93 Set Length 2 50 Chars Code 93 Minimum Reads 1 Read Code 93 Decoding Level...
  • Page 360: Default Exceptions

    Code Standard 2/5 Label ID Character(s) Codabar Label ID Character(s) Code 128 Label ID Character(s) GS1-128 Label ID Character(s) Datalogic 2 of 5 Label ID Character(s) ISBT 128 Label ID Character(s) UPCE P2 Label ID Character(s) UPCE/P5 Label ID Character(s)
  • Page 361 Default Exceptions Parameter Default Excption EAN8/P2 Label ID Character(s) EAN8/P5 Label ID Character(s) EAN8/GS1-128 Label ID Character(s) EAN13/P2 Label ID Character(s) EAN13/P5 Label ID Character(s) EAN13/GS1-128 Label ID Character(s) GS1 DataBar 14 (Omnidirectional) Label ID Character(s) GS1 DataBar Expanded Label ID Character(s) GS1 DataBar Limited Label ID Character(s) Character Conversion CR to `...
  • Page 362 Parameter Default Excption UPCE/P5 Label ID Character(s) EAN8/P2 Label ID Character(s) EAN8/P5 Label ID Character(s) EAN8/GS1-128 Label ID Character(s) EAN13/P2 Label ID Character(s) EAN13/P5 Label ID Character(s) EAN13/GS1-128 Label ID Character(s) GS1 DataBar 14 (Omnidirectional) Label ID Character(s) GS1 DataBar Expanded Label ID Character(s) GS1 DataBar Limited Label ID Character(s) GTIN W/o Add on Label ID Character(s) GTIN Addon 2 Label ID Character(s)
  • Page 363: Appendix C. Led And Beeper Indications

    Appendix C LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on.
  • Page 364: Led And Beeper Indications

    LED and Beeper Indications INDICATION DESCRIPTION BEEPER Reader beeps four times at highest The reader is in the process of pow- Power-up Beep frequency and volume upon power- ering-up. LED behavior for this indica- The reader will beep once at current A label has been successfully tion is configurable via the frequency, volume, mono/bi-tonal...
  • Page 365: Error Codes

    Error Codes Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU isolation mode. If the reader is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.
  • Page 366 NOTES PowerScan PD7100 Corded...
  • Page 367: Appendix D Sample Barcodes

    Appendix D Sample Barcodes The sample barcodes in this appendix are typical representations for their symbology types. UPC-A 12345 67890 EAN-13 3 4 5 67 8 9 0 1 2 3 4 0 Code 39 123ABC Code 128 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 Interleaved 2 of 5 12345678901231 Product Reference Guide...
  • Page 368: Codabar

    Sample Barcodes — continued Code 32 Codabar Code 93 Code 11 PowerScan PD7100 Corded...
  • Page 369: Gs1 Databar (Rss)

    GS1 DataBar (RSS) GS1 DataBar (RSS) GS1 DataBar variants must be enabled to read the barcodes below (see DataBar (RSS) on page 359 NOTE 10293847560192837465019283746029478450366523 (GS1 DataBar Expanded Stacked) 1234890hjio9900mnb (GS1 DataBar Expanded) 08672345650916 (GS1 DataBar Limited) GS1 DataBar-14 55432198673467 (GS1 DataBar Omnidirectional Truncated) 90876523412674 (GS1 DataBar Omnidirectional Stacked)
  • Page 370 NOTES PowerScan PD7100 Corded...
  • Page 371: Appendix E Keypad

    Appendix E Keypad Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad. Product Reference Guide...
  • Page 372 PowerScan PD7100 Corded...
  • Page 373 Product Reference Guide...
  • Page 374 NOTES PowerScan PD7100 Corded...
  • Page 375: Appendix F. Scancode Tables

    Appendix F Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appen- dix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms. Control Character 00 —...
  • Page 386: Microsoft Windows Codepage 1252

    Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg- acy components of Microsoft Windows in English and some other Western languages. PowerScan PD7100 Corded...
  • Page 387 Microsoft Windows Codepage 1252 NOTES Product Reference Guide...
  • Page 388 NOTES PowerScan PD7100 Corded...
  • Page 389: Index

    Index Ambient Light Immunity eading/trailing noise Electrical Safety EMI/RFI Error Codes Errors bar codes RS-232 baud rate RS-232 parameters parity Good Read, Beeper 326, 328, 331, barcodes Pitch cancel Volume numeric barcodes Good Read, Beeper – RS-232 parameters Good Read, Beeper Pitch – parity Good Read, Beeper Volume –...
  • Page 390 select digits/characters Serial Output Light Source Signal Speed (wand) Skew (Yaw) Tolerance Standard Cable Pinouts Storage Temperature Mixed OEM Standard + Code 39 For- Suffix Symbology Conversion symbology types numbers lock key Table Top Scanner 86, 87, trailing noise Operating Temperature USB Connection Performance Characteristics USB interface selection...
  • Page 391 ASCII Chart ASCII ASCII ASCII ASCII Hex No. Hex No. Hex No. Char. Char. Char. Char. ‘ “ & ’ < >...
  • Page 392 Telephone: 49 (0) 61 51/93 58-0 Telephone: (65) 6435-1311 germany.scanning@datalogic.com singapore.scanning@datalogic.com India Iberia Datalogic Scanning India Datalogic Scanning SAS Sucursal en España Telephone: 91- 22 - 64504739 Telephone: 34 91 746 28 60 india.scanning@datalogic.com spain.scanning@datalogic.com Italy United Kingdom Datalogic Scanning SpA Datalogic Scanning LTD Telephone: [39] (0) 39/62903.1...

Table of Contents