Datalogic PowerScan PD7100 Corded Product Reference Manual page 112

Linear imaging barcode reader
Hide thumbs Also See for PowerScan PD7100 Corded:
Table of Contents

Advertisement

Data Editing
Label ID — continued
Table 18. Label ID Examples
STEP
ACTION
1.
Scan the ENTER/EXIT barcode
Determine placement of the Label
ID characters BEFORE or AFTER
with regard to scanned data using
2.
Label ID Control on
page 105
Scan the barcode selecting the
symbology type you wish to
designate label ID characters for
3.
Label ID Symbology
using
Selection, starting on page
106
.
Custom Label ID example (desired
4.
characters):
Find hex equivalents from the
ASCII table (inside back cover),
then scan in these digits/
characters using the barcodes in
Keypad, starting
the section:
5.
on page 295
. f you make a
mistake before the last character,
scan the CANCEL barcode to
abort and not save the entry
string. You can then start again at
the beginning.
6.
Scan theENTER/EXIT barcode
Scan the ENTER/EXIT barcode
7.
once again
Result:
104
(Scanner enters Programming Mode)
Enable as Prefix
Enable as Suffix
GS1 DataBar
Code 39
Omnidirectional
D B *
= C 3
44 42 2A
3D 43 33
(Scanner exits Label ID entry)
(Scanner exits Programming Mode)
DB*[barcode data] [barcode data]=C3 +[barcode data]
EXAMPLES
Enable as Prefix
Interleaved 2 of 5
+
2B
®
PowerScan
PD7100 Corded
Enable as Suffix
Code 32
P H
50 48
[barcode data]PH

Advertisement

Table of Contents
loading