Show Power Inline - Cisco WS-C3560E-24PD-E Command Reference Manual

Catalyst 3560 series switch
Table of Contents

Advertisement

Chapter 2 Catalyst 3560 Switch Cisco IOS Commands
Interface Admin
--------- ------ ---------- ------- ------------------- ----- ----
Fa0/1
This is an example of output from the show power inline consumption default command on all PoE
switch ports:
Switch> show power inline consumption default
Default PD consumption : 15400 mW
Table 2-30
Field
Admin
Oper
Power
Device
Class
Available
Used
Remaining
Related Commands
Command
logging event
power-inline-status
power inline
show controllers
power inline
78-16405-05
Oper
Power
(Watts)
auto
on
6.3
show power inline interface Field Descriptions
Description
Administration mode: auto, off, static
Operating mode:
on—the powered device is detected, and power is applied.
off—no PoE is applied.
faulty—device detection or a powered device is in a faulty state.
power-deny—a powered device is detected, but no PoE is available, or the
maximum wattage exceeds the detected powered-device maximum.
The supplied PoE in watts
The device type detected: n/a, unknown, Cisco powered-device, IEEE
powered-device, <name from CDP>
The IEEE classification: n/a, Class <0–4>
The total amount of PoE in the system
The amount of PoE allocated to ports
The amount of PoE not allocated to ports in the system. (Available – Used =
Remaining)
Description
Enables the logging of PoE events.
Configures the power management mode for the specified PoE port or for all
PoE ports.
Displays the values in the registers of the specified PoE controller.
Device
Class Max
IP Phone 7910
n/a
Catalyst 3560 Switch Command Reference

show power inline

15.4
2-513

Hide quick links: