show env

show env
Use the show env user EXEC command to display fan, temperature, redundant power system (RPS)
availability, and power information for the switch.
Syntax Description
all
fan
power
rps
temperature
status
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.1(19)EA1
12.2(20)SE3
Usage Guidelines
Though visible on all switches, the show env temperature status command is valid only for the
Catalyst 3560G-48TS, 3560G-48PS, 3560G-24TS, and 3560G-24PS switches. If you enter this
command on these switches, the command output shows the switch temperature states and the threshold
levels. If you enter the command on a switch other than these four switches, the output field shows
Applicable
On a Catalyst 3560G-48PS or 3560G-24PS switch, you can also use the show env temperature
command to display the switch temperature status. The command output shows the green and yellow
states as OK and the red state as FAULTY. If you enter the show env all command on this switch, the
command output is the same as the show env temperature status command output.
For more information about the threshold levels, see the software configuration guide for this release.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
Catalyst 3560 Switch Command Reference
2-388
show env {all | fan | power | rps| temperature [status]} [ | {begin | exclude | include} expression]
Display both fan and temperature environmental status.
Display the switch fan status.
Display the switch power status.
Display whether an RPS 300 Redundant Power System is connected to the switch.
Display the switch temperature status.
(Optional) Display the switch internal temperature (not the external temperature)
and the threshold values. This keyword is available only on the
Catalyst3560G-48TS, 3560G-48PS, 3560G-24TS, and 3560G-24PS switches.
(Optional) Display begins with the line that matches the expression.
(Optional) Display excludes lines that match the expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced.
The temperature status keyword was added.
.
Chapter 2 Catalyst 3560 Switch Cisco IOS Commands