Chapter 2 Catalyst 3560 Switch Cisco IOS Commands
Do not enable the root guard on interfaces that will be used by the UplinkFast feature. With UplinkFast,
the backup interfaces (in the blocked state) replace the root port in the case of a failure. However, if root
guard is also enabled, all the backup interfaces used by the UplinkFast feature are placed in the
root-inconsistent state (blocked) and prevented from reaching the forwarding state.
If you set the max-update-rate to 0, station-learning frames are not generated, so the spanning-tree
topology converges more slowly after a loss of connectivity.
Examples
This example shows how to enable UplinkFast:
Switch(config)# spanning-tree uplinkfast
You can verify your setting by entering the show spanning-tree summary privileged EXEC command.
Related Commands
Command
show spanning-tree
spanning-tree vlan
78-16405-05
Description
summary
Displays a summary of the spanning-tree interface states.
root primary
Forces this switch to be the root switch.
spanning-tree uplinkfast
Catalyst 3560 Switch Command Reference