Rom Monitor Cli; Example Of A Catalyst 4003 Bootup Display - Cisco WS-C2950SX-48-SI Configuration Manual

Catalyst 4500 series switches
Hide thumbs Also See for WS-C2950SX-48-SI:
Table of Contents

Advertisement

Chapter 2
Using the Command-Line Interface

ROM Monitor CLI

The ROM monitor is a ROM-based program that executes when the switch is powered on, reset, or when
a fatal exception occurs. The system enters ROM monitor mode if the nonvolatile RAM (NVRAM)
configuration is corrupted, if the switch does not find a valid system image, or if the configuration
register is set to enter ROM monitor mode. From the ROM monitor mode, you can load a system image
manually from Flash memory or the network interface (me1).
You can enter ROM monitor mode by pressing Ctrl-C within the first 5 seconds of startup. Once you are
in ROM monitor mode, the prompt changes to rommon>. Enter the ? command to see the available ROM
monitor commands.
For complete descriptions of all ROM monitor commands, refer to the Catalyst 4500 Series, Catalyst
Note
2948G, and Catalyst 2980G Switches Command Reference.

Example of a Catalyst 4003 Bootup Display

This example shows the bootup display of a Catalyst 4003 switch. The display on the Catalyst 4912G,
the Catalyst 2948G, and the Catalyst 2980G switches are similar.
WS-X4012 bootrom version 4.5(1), built on 1999.03.29 21:04:04
H/W Revisions:
Supervisor MAC addresses: 00:d0:58:70:a1:00 through 00:d0:58:70:a4:ff (1024 addresses)
Installed memory: 32 MB
Testing LEDs.... done!
The system will autoboot in 5 seconds.
Type control-C to prevent autobooting.
rommon 1 >
The system will now begin autobooting.
Autobooting image: "bootflash:cat4000.5-1-1a.bin"
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCC############################
Starting Off-line Diagnostics
Mapping in TempFs
Board type is WS-X4012
DiagBootMode value is "post"
Loading diagnostics...
Power-on-self-test for Module 1:
Status: (. = Pass, F = Fail)
processor: .
enet console port: .
switch registers: .
switch port 2: .
switch port 5: .
switch port 8: .
switch port 11: .
Module 1 Passed
Power-on-self-test for Module 2:
Port status: (. = Pass, F = Fail)
1: .
9: .
17: .
25: .
33: .
78-15486-01
Meteor: 4
cpu sdram: .
nvram: .
switch port 0: .
switch port 3: .
switch port 6: .
switch port 9: .
switch bandwidth: .
2: .
3: .
4: .
10: .
11: .
12: .
13: .
18: .
19: .
20: .
21: .
26: .
27: .
28: .
29: .
34: .
35: .
36: .
37: .
Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide
Comet: 8
Board: 2
WS-X4012
temperature sensor: .
switch sram: .
switch port 1: .
switch port 4: .
switch port 7: .
switch port 10: .
WS-X4148
5: .
6: .
7: .
8: .
14: .
15: .
16: .
22: .
23: .
24: .
30: .
31: .
32: .
38: .
39: .
40: .
ROM Monitor CLI
Release 8.1
2-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents