Cisco WS-C2950SX-48-SI Configuration Manual page 244

Catalyst 4500 series switches
Hide thumbs Also See for WS-C2950SX-48-SI:
Table of Contents

Advertisement

Example VLAN Trunk Configurations
Vlan 40 configuration successful
Switch_1> (enable) set vlan 50
Vlan 50 configuration successful
Switch_1> (enable) set vlan 60
Vlan 60 configuration successful
Switch_1> (enable)
Verify the VTP and VLAN configuration on Switch 1 by entering the show vtp domain and show vlan
Step 3
commands:
Switch_1> (enable) show vtp domain
Domain Name
-------------------------------- ------------ ----------- ----------- ----------
BigCorp
Vlan-count Max-vlan-storage Config Revision Notifications
---------- ---------------- --------------- -------------
11
Last Updater
--------------- -------- -------- -------------------------
172.20.52.10
Switch_1> (enable) show vlan
VLAN Name
---- -------------------------------- --------- ----------------------------
1
10
11
20
30
40
50
60
1002 fddi-default
1003 token-ring-default
1004 fddinet-default
1005 trnet-default
.
.
.
Switch_1> (enable)
Step 4
Configure the supervisor engine uplinks on Switch 1 as 802.1Q trunk ports by entering the set trunk
command. Specifying the desirable mode on the Switch 1 ports causes the ports on Switch 2 to negotiate
to become trunk links (assuming that the Switch 2 uplinks are in the default auto mode).
Switch_1> (enable) set trunk 1/1 desirable
Port(s)
2000 Jul 12 01:56:28 %DTP-5-TRUNKPORTON:Port 1/1 has become dot1q trunk
Switch_1> (enable)
Switch_1> (enable) set trunk 1/2 desirable
Port(s)
2000 Jul 12 01:56:52 %DTP-5-TRUNKPORTON:Port 1/2 has become dot1q trunk
Switch_1> (enable)
Verify that the trunk links are up by entering the show trunk command:
Step 5
Switch_1> (enable) show trunk 1
* - indicates vtp domain mismatch
Port
--------
Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide
11-14
1023
V2 Mode
Pruning
disabled enabled
default
VLAN0010
VLAN0011
VLAN0020
VLAN0030
VLAN0040
VLAN0050
VLAN0060
1/1 trunk mode set to desirable.
1/2 trunk mode set to desirable.
Mode
Encapsulation
-----------
-------------
Chapter 11
Configuring VLAN Trunks on Fast Ethernet and Gigabit Ethernet Ports
Domain Index VTP Version Local Mode
1
2
13
disabled
PruneEligible on Vlans
2-1000
Status
Mod/Ports, Vlans
active
1/1-2
2/1-12
5/1-2
active
active
active
active
active
active
active
active
active
active
active
Status
------------
Password
server
-
Native vlan
-----------
Release 8.1
78-15486-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents