The And Block - SMC Networks aPNEUALPHA2 Series Programming Manual

Simple application controller
Table of Contents

Advertisement

α
PneuAlpha2 Simple Application
5.1

The AND Block

The AND block comes ON when all the inputs are ON.
Any Input that is OFF will keep the Output turned OFF.
Unused inputs are considered to be ON.
If no Input pins are connected, the block output is OFF.
Table 5.2: AND Logic gate
Input 1
On
On
On
On
Off
On
On
Off
Off
On
Off
On
Off
Off
Off
Off
Input 2
Input 3
On
On
On
On
On
Off
Off
On
On
On
On
Off
Off
Off
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
On
Off
Off
Off
Off
Input 4
Output
On
On
Off
Off
On
Off
On
Off
On
Off
Off
Off
On
Off
On
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
The Logic Function Blocks 5