I/O Circuit Diagrams; Amplifier Unit - Omron ZX Series Manual

Displacement sensor and parallel beam sensor
Hide thumbs Also See for ZX Series:
Table of Contents

Advertisement

ZX SERIES
Installation

I/O Circuit Diagrams

NPN Amplifier Unit: ZX-LDA11
Current output
Current/voltage
4 to 20 mA
switch
Voltage output
±4V
100 Ω
Connections

Amplifier Unit

Note:
1. Use a separate stabilized power supply for the Amplifier Unit,
particularly when high resolution is required.
2. Wire the Unit correctly. Incorrect wiring may result in damage
to the Unit. (Do not allow wiring, particularly the linear output,
to come into contact with other lines.)
3. Use the 0-V line (blue) for the power supply and use the
shield wire (linear output ground) together with the linear out-
put (black line) for linear output. Each of these grounds must
be used for the designed purpose. When not using the linear
output, connect the linear ground (shield) to the 0-V ground.
Brown: 12 to 24 VDC
White: HIGH
output
Green: PASS output
12 to
24 VDC
Gray: LOW output
Blue: GND (0V)
Pink: Laser OFF input
Purple: Timing input
Orange: Zero reset input
Red: Reset input
Black: Linear output
Current output: 300 Ω max.
Voltage output: 10 kΩ min.
Shield: Linear GND
Brown:
12 to 24 VDC
Blue:
GND (0V)
White:
HIGH output
Green:
PASS output
Gray:
LOW output
Black:
Linear output
Shield:
Linear output GND
Pink:
Laser OFF input
Orange:
Zero reset input
Purple:
Timing input
Red:
Reset input
PNP Amplifier Unit: ZX-LDA41
Current output
4 to 20 mA
Current/voltage
switch
Voltage output
±4V
100 Ω
ZX SERIES
Brown: 12 to 24 VDC
White: HIGH output
Green: PASS output
12 to
24 VDC
Gray: LOW output
Blue: GND (0V)
Pink: Laser OFF input
Purple: Timing input
Orange: Zero reset input
Red: Reset input
Black: Linear output
Current output: 300 Ω max.
Voltage output: 10 kΩ min.
Shield: Linear GND
23

Advertisement

Table of Contents
loading

Table of Contents