Data Movement Instructions
Operands
Operand Specifications
340
S: Source Word
The source digits are read from right to left, wrapping back to the rightmost
digit (digit 0) if necessary.
S
C: Control Word
The first three digits of C indicate the first source digit (m), the number of dig-
its to transfer (n), and the first destination digit (l), as shown in the following
diagram.
15
12
C
0
Always 0.
D: Destination Word
The destination digits are written from right to left, wrapping back to the right-
most digit (digit 0) if necessary.
D
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
15
12
11
8
7
4
Digit 3
Digit 2
Digit 1
11
8
7
4
3
0
l
n
m
First digit in S (m): 0 to 3
Number of digits (n): 0 to 3
First digit in D (l): 0 to 3
15
12
11
8
7
4
Digit 3
Digit 2
Digit 1
S
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A000 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
#0000 to #FFFF
Specified values
(binary)
only
DR0 to DR15
Section 3-8
3
0
Digit 0
0: 1 digit
1: 2 digits
2: 3 digits
3: 4 digits
3
0
Digit 0
C
D
A448 to A959
---

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cs seriesSysmac one nsj seriesSysmac cj series

Table of Contents