Conversion Instructions

3-12-4 DOUBLE BINARY TO DOUBLE BCD: BCDL(059)

Purpose
Ladder Symbol
Variations
Applicable Program Areas
Operands
Operand Specifications
00000
MOVR
D10
IR0
MOVR
D100
IR1
FOR
&3
00000
BCD
,IR0+
,IR1+
NEXT
Converts 8-digit hexadecimal (32-bit binary) data to 8-digit BCD data.
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Block program areas
OK
OK
S: First Source Word
The content of S+1 and S must be between 0000 0000 and 05F5 E0FF hexa-
decimal (0000 0000 and 9999 9999 decimal).
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
D00010
Decimal &100
D00011
Decimal &200
D00012
Decimal &300
BIN
BCD
D00100
BCD #0100
D00101
BCD #0200
D00102
BCD #0300
BCDL(059)
S
R
Step program areas
Subroutines
OK
S
CIO 0000 to CIO 6142
W000 to W510
H000 to H510
A000 to A958
T0000 to T4094
C0000 to C4094
D00000 to D32766
Section 3-12
(Hexadecimal #0064)
(Hexadecimal #00C8)
(Hexadecimal #012C)
S: First source word
R: First result word
BCDL(059)
@BCDL(059)
Not supported
Interrupt tasks
OK
R
A448 to A958
489