I/O Allocation For The Shutter Control System - Omron CP1E - INTRODUCTION Introduction Manual

Cp1l/cp1e cpu unit
Hide thumbs Also See for CP1E - INTRODUCTION:
Table of Contents

Advertisement

2

2-3 I/O Allocation for the Shutter Control System

2-3 I/O Allocation for the Shutter Control System

I/O relays on CP1L are allocated to contacts as defined by following.
Inputs
2
Outputs
26
SYSMAC CP1L/CP1E Introduction Manual
Device
Contact
OPEN button
PB1
STOP button
PB2
CLOSE button
PB3
Car detection
SEN1
sensor
Light detection
SEN2
sensor
Upper limit LS
LS1
Lower limit LS
LS2
Device
Contact
Escalation motor
MO1
De-escalation motor
MO2
LS1(0.05)
MO1(100.00)
MO2(100.01)
LS2(0.06)
Address
0.00
0.01
0.02
0.03
0.04
0.05
0.06
Address
100.00
100.01
SEN2(0.04)
PB1(0.00)
PB2(0.01)
PB3(0.02)
SEN1(0.03)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents