Omron CP1E - INTRODUCTION Introduction Manual page 137

Cp1l/cp1e cpu unit
Hide thumbs Also See for CP1E - INTRODUCTION:
Table of Contents

Advertisement

Programming Example
Ladder Program
(A): Turned ON for Monday thru Friday (i.e. when A354 [day] is less than or equal
to [Friday]),
from 17:30 (when A351 [hh:mm:ss] becomes equal to the value set in D0
[17:30:00])
until 20:30 (when A351 [hh:mm:ss] becomes equal to the value set in D10
[20:30:00]).
(B): Turned ON for Saturday and Sunday (i.e. when A354 [day] is equal to
[Saturday]) or [Sunday],
from 10:00 (when A351 [hh:mm:ss] becomes equal to the value set in D20
[10:00:00])
until 21:15 (when A351 [hh:mm:ss] becomes equal to the value set in D30
[21:15:00]).
• >=DT and <DT are time comparison instructions.
<=(315)
>=DT(346)
A354
#38
#5
A351
D0
=(300)
>=DT(346)
A354
#38
#6
A351
D20
=(300)
A354
#0
A-4 CP1L Programming Examples
<DT(343)
#38
A351
D10
<DT(343)
#38
A351
D30
SYSMAC CP1L/CP1E Introduction Manual