Omron CJ - REFERENCE MANUAL 02-2010 Reference Manual page 277

Table of Contents

Advertisement

0.00
Timer input
0.00
Reset bit
100.08
Pause bit
100.09
Max. PV = 9999
Timer SVs
SV 7
SV 1
SV 0
Completion Flags
CS/CJ/NSJ Series Instructions Reference Manual (W474)
D100
D1: 100CH
D200
Timer PV
D2: D100
Timer SVs
S: D200
S+1: D201
S+2: D202
S+3: D203
S+4: D204
S+5: D205
S+6: D206
S+7: D207
PV maintained.
Completion Flags
Reset bit
Pause bit
(Incrementing)
Corresponding completion
flag ON when SV
Timer input must remain ON
while the timer is timing.
Timing resumes.
3. Instructions
PV.
3