Omron CJ - REFERENCE MANUAL 02-2010 Reference Manual page 758

Table of Contents

Advertisement

3. Instructions
Setting the Time to the First Scheduled Interrupt
W0.00
W0.01
Scheduled interrupt 0 (interrupt task 2)
Cyclic task
1. Execution of CLI(691)
(Sets 24 ms to first task.)
722
1 When W0.00 goes from OFF to ON, CLI(691) sets the time to
@CLI
the first execution of scheduled interrupt 0 to 24 ms. (In this
N
4
case, the scheduled interval time unit is set to 1 ms in the
PLC Setup.)
C
&24
2 When W0.01 goes from OFF to ON, CLI(691) sets the time to
the first execution of scheduled interrupt 0 to 12 ms, and
@MSKS
starts the internal timer. (In this case, the scheduled time
N
4
interval units are set to 1 ms in the PLC Setup.)
C
&12
2. Execution of CLI(691)
(Enables interrupt and sets 12 ms.)
24 ms
12 ms
12 ms
CS/CJ/NSJ Series Instructions Reference Manual (W474)