WARNING status
The WARNING is an anomalous event related to a malfunction of the device. The WARNING does not
compromise the functioning of the device and the safety of operators.
NOTE
INFORMATION
Code
78 | 118
WARNING status
With the device in WARNING status the compressed air treatment may be
improper.
•
Call immediately the maintenance personnel if one or more WARNINGS
are detected.
•
Maintenance personnel will refer to section "16 Troubleshooting" on page
107.
Behaviour of the device in presence of a WARNING
•
With the device stopped: the triggering of a WARNING is not shown on the
User Interface. In a presence of a WARNING, normally, is possible to start
the device. After the starting, the WARNING code will be shown on the
User Interface.
•
With the device started: the triggering of a WARNING, normally, does not stop
the device.
•
Only HdP WARNING can be set:
- to prevent the starting of the device, if stopped.
- to stop the device, if started.
Description / explanation
HdP – Dew point temperature too high.
LdP – Dew point temperature too low.
drn – Condensate drain, defective or faulty.
SrV – Maintenance of the device, time expired.
dt – Refrigerant fluid, temperature too high.
LEP – Refrigerant fluid, low evaporating pressure.
HCP – Refrigerant fluid, high condensing pressure.