DRYPOINT
®
RA III
9.3.1
Normal running status
INFORMATION
INFORMATION
Illustration
Dew point value
A dew point between 0 °C (+32 °F) and +10 °C (+50 °F) displayed on the User
Interface is considered to be correct according to the possible operating
conditions, e.g flow rate, air inlet temperature, ambient temperature, etc.
Refrigerant compressor running
During the normal running status, the refrigerant compressor runs continuously.
The product must remain started during the entire compressed air usage time,
even if the air compressor works periodically.
Original installa�on and opera�on manual
Description / explanation
Normal running status
•
Status LED HOME [L8] is lit.
•
Status LED REFRIGERANT
COMPRESSOR [L11] is lit.
•
Status LED TEMPERATURE °C [L5] is lit.
•
MAIN display [L1] shows the dew point
temperature.
•
SECONDARY display [L2] shows PdP
•
If the cooling fan is running, the status LED
COOLING FAN [L12] is lit.
73 | 118