DRYPOINT
®
RA III
14.2 Disassembly work
For disassembly work to be carried out, the following protective equipment must be always worn and the
preparatory tasks must have been completed.
Tools
•
No tool necessary
The procedure on section "13 Decommissioning" on page 99 was carried out.
1.
Have the necessary tools ready.
2.
1.
Disconnect the power cable from the protective contact socket / terminal box.
Uninstall collision protection, if was installed.
2.
Disconnect the condensate drain hose to the drain collection line.
3.
Water-cooled models: disconnect the threaded connection to the cooling water line.
4.
Disconnect the threaded connection to the compressed air line.
5.
Remove fixing bolts if the product was fixed on the floor.
6.
Remove the service panels on the product.
7.
8.
Remove from the place of installation all disassembled parts and accessories.
Remove the refrigerant fluid from the refrigerant circuit.
9.
Clean the installation area from any fluid or oil leakage occurred during the disassembly
10.
work.
Prerequisites
Material
•
No material necessary
Preparatory tasks
Disassembly work