Beko DRYPOINTRA III 20 Translation Of Original Installation And Operation Manual page 108

Compressed air refrigeration dryer
Table of Contents

Advertisement

Original installa�on and opera�on manual
Resetting a WARNING (except SrV "maintenance time expired")
Refer to the section "3.2 User Interface" on page 29.
1.
Refer to the section "9.3.5
2.
WARNING status" on page78.
3.
Fix the cause which has triggered the WARNING.
The status LED WARNING [L14] is lit.
4.
Press 2 times the ENTER/CONFIRM button [B6].
5.
The status LED WARNING [L14] goes out.
6.
Resetting the WARNING SrV "maintenance time expired"
Refer to the section "3.2 User Interface" on page 29.
1.
Refer to the section "9.3.4 Live data" on page 76.
2.
Follow steps 1. to 6. and select SrV
3.
Keep pressed the ENTER/CONFIRM button [B6] for 5 seconds, MAIN display [L1] shows
4.
"rES".
Press again the ENTER/CONFIRM button [B6] to initialize the maintenance timer to its present
5.
value.
Press repeatedly the NAVIGATION button [B2] or [B3] to select ESC
6.
7.
Press the ENTER/CONFIRM button [B6] to exit the LIVE DATA.