Transport And Storage; Installation; Maintenance - Beko DRYPOINTRA III 20 Translation Of Original Installation And Operation Manual

Compressed air refrigeration dryer
Table of Contents

Advertisement

DRYPOINT
®
RA III
2.5.5

Transport and storage

Inappropriate transport or storage may result in personal injury or damage to property.
For safe transport and storage of the product and accessories, observe the following point:
Handle the packaging, the product and accessories carefully.
Transport and handle the packaged product and accessories according to the markings on the
packaging (note lifting gear attachment points, the centre of gravity and alignment e.g. keep vertical,
do not throw, etc.).
Only use proper means of transport and lifting equipment that is in proper working order.
Always adhere to the permissible storage parameters.
Store the product and accessories only outside of areas exposed to direct sunlight and heat sources.
2.5.6

Installation

Inappropriate assembly or electrical installation of the product and accessories may result in personal injury
and damage to property as well as impair operation.
For safe assembly and electrical installation, observe the following points:
Assemble the product and all parts, accessories and materials used free of mechanical stress.
Check all plug-type connections for a correct fit.
Avoid stumbling risks by routing cables and hoses accordingly.
Avoid mechanical strain on the cables.
Fix and fasten hoses in such a way that they cannot flap around.
Install air inlet/outlet line and drain line as a fixed pipes.
2.5.7

Maintenance

Improper performance of maintenance and repair work may result in serious personal injuries or death.
For safe maintenance and repair, observe the following points:
Before starting work, depressurise the pressurised product and accessories and secure them against
unintentional pressurisation.
Before starting work, disconnect the product and accessories and secure them against being switched
back ON again unintentionally.
The product contains fluorinated greenhouse refrigerant fluid. Observe the requirements indicated on
the safety data sheet of the refrigerant fluid during all maintenance, repair and emptying operations
of the refrigerant circuit.
Original installa�on and opera�on manual
15 | 118

Advertisement

Table of Contents
loading