Beko DRYPOINTRA III 20 Translation Of Original Installation And Operation Manual page 113

Compressed air refrigeration dryer
Table of Contents

Advertisement

DRYPOINT
®
RA III
Specific
malfunction
Probe BT2,
compressor
discharge
temperature too
high.
From previous page
Probe BT2,
compressor
discharge
temperature too
high.
Transducer BLP,
Evaporating
pressure of
refrigerant fluid too
low.
Cause
The probe BT2 does not detect the
temperature correctly.
Excessive thermal load.
The temperature of inlet compressed air
is too high.
The ambient temperature is too high or
ventilation is insufficient.
The condenser is dirty.
The cooling fan is stopped.
There is a refrigerant leak in the
refrigerant circuit.
The hot gas by-pass valve is out of
calibration.
There is a refrigerant leak in the
refrigerant circuit.
The hot gas by-pass valve is out of
calibration.
The transducer BLP is defective.
The cooling fan is running continuously.
Original installa�on and opera�on manual
Action
Check / place the probe back in its
correct position.
Restore the nominal operating
conditions.
Clean the condenser.
See specific malfunction "The cooling
fan is stopped".
Repair the refrigerant circuit.
Refer to section "11.2.1 Adjustment of
hot gas by-pass valve" on page 92.
Repair the refrigerant circuit.
Refer to section "11.2.1 Adjustment of
hot gas by-pass valve" on page 92.
Replace the transducer.
Replace the Electronic Control Unit.
113 | 118