DRYPOINT

®
RA III
4.1.1
DRYPOINT
Parameter
Air flow rate at
nominal conditions
Air pressure drop
Cooling air fan flow
Heat rejection
Refrigerant quantity
Power supply
Nominal electric
consumption @ 50 Hz
Nominal electric
consumption @ 60 Hz
Full load amperage
RA III 20 ... 135
®
Unit
20
m
/h
21
3
l/min
350
scfm
12
Bar
0,03
(psi)
(0.44)
m
/h
3
(cfm)
kW
0,56
(btu/h)
(1911)
Kg
0,14
(oz)
(5)
V/ph/f
kW
0,12
A
0,8
kW
0,13
A
0,8
A
1,0
Original installa�on and opera�on manual
DRYPOINT
®
35
50
33
51
550
850
19
30
0,06
0,06
(0.87)
(0.87)
(1.60)
200
(118.7)
0,88
1,20
(3003)
(4095)
(5801)
0,16
0,20
(5.¾)
(7)
230/1/50-60
0,19
0,20
1,3
0,20
1,2
1,8
RA III
70
110
135
72
108
138
1200
1800
2300
42
64
0,11
0,04
0,06
(0.58)
(0.87)
300
(176.6)
1,70
2,60
3,30
(8872)
(11260)
0,24
0,28
0,35
(8.½)
(10)
(12.¼)
0,30
0,32
0,54
2,1
0,35
0,37
0,56
2,0
3,3
35 | 118
81
3,1
2,5
5,3