Beko DRYPOINTRA III 20 Translation Of Original Installation And Operation Manual page 116

Compressed air refrigeration dryer
Table of Contents

Advertisement

Original installa�on and opera�on manual
Specific
malfunction
The cooling fan is
stopped.
The device does not
drain the
condensate.
The device
continuously drains
condensate.
Excessive air
pressure drop.
116 | 118
Cause
The internal heat protection, where
available, has triggered.
The internal heat protection, where
available, is defective.
The starting capacitor, where available,
is defective.
There is a refrigerant leak in the
refrigerant circuit.
The electrical wiring is interrupted.
The transducer BHP is defective.
The motor is faulty.
The pressure of compressed air is too
low.
The condensate service valve is closed.
The condensate is frozen.
The BEKOMAT
condensate drain does
®
not work properly.
The BEKOMAT
condensate drain does
®
not work properly.
The condensate is frozen.
The device does not drain the
condensate.
The heat exchanger is clogged.
Action
Wait 30 minutes to cool down the
motor.
Replace the motor.
Replace the capacitor.
Repair the refrigerant circuit.
Restore the electrical wiring.
Replace the transducer.
Replace the motor.
Restore the nominal operating
conditions.
Open the valve.
See specific malfunction "Probe BT1,
dew point temperature too low".
Consult BEKOMAT
Installation and
®
operation manual.
Consult BEKOMAT
Installation and
®
operation manual.
See specific malfunction "Probe BT1,
dew point temperature too low."
See specific malfunction "The device
does not drain the condensate."
Check and clean the heat exchanger.
DRYPOINT
®
RA III