Dial Line Configuration Options — Multiport Mode - Paradyne COMSPHERE 3920PLUS Technical Reference Manual

Zhone comsphere 3920plus modems: reference guide
Hide thumbs Also See for COMSPHERE 3920PLUS:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
Dial Line — Multiport Mode l
The Dial Line configuration options are used to configure the modem for operation over dial lines.
Table 5-3 shows each Dial Line configuration option as it appears on the LCD, with the Sync
Leased factory default setting (the default value if the modem is just being installed) shown
following the colon ( : ) on the first line and with all available selections listed on the second line.
Following this is a description of the configuration option. Factory default settings are listed in
Appendix F,
Dial Modulation: V34
Nxt V34 V32_Family
Dial Modulation. Modulation reduces the amount of scrolling necessary to select Dial Line rates by limiting the number
of Dial Line Rate configuration options. Only one group of Dial Line rates is displayed depending on the setting of the
Dial Modulation configuration option (V.34, V.32bis, and V.32terbo).
Dial Line Rate: 33600(V34)
Nxt 33600(V34) 28800(V34) 24000(V34) 21600(V34) 19200(V34) 16800(V34) 14400(V34) 12000(V34)
9600(V34) 7200(V34) 4800(V34) 2400(V34) 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b)
9600(V32b) 7200(V32b) 4800(V32b)
Dial Line Rate. This configuration option determines the modem's data rate and modulation scheme for operation on dial
lines. Online changes do not take effect until a disconnect occurs.
NOTE: Certain changes to this configuration option will cause the modem to reset.
33600(V34), 28800(V34), 24000(V34), 21600(V34), 19200(V34), 16800(V34), 14400(V34), 12000(V34), 9600(V34),
7200(V34), 4800(V34), 2400(V34) – The modem operates using V.34 modulation at the data rate selected.
19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) – The modem operates
using V.32terbo, V.32bis, or V.32 modulation at the data rate selected.
Start at 48 and Start at 96 – Set the maximum connect rate for V.32, V.32bis, and V.32terbo connections.
Autorate: Enable
Nxt Enable Disable StartAt48 StartAt96 Fast
Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line
conditions improve, the modem automatically shifts up to the highest data rate the line can support. Autorate only
occurs between 19,200 bps and 4800 bps during V.32, V.32bis, and V.32terbo connections and 33.6 and 2400 bps for
the V.34 family.
Start at 48 and Start at 96 – Set the maximum connect rate for V.32, V.32bis, and V.32terbo connections.
Fast – Autorate is enabled and tuned to minimize bit errors.
V32bis Override: Disable
Nxt Disable 2400
This configuration option is ignored unless Dial Line Rate is 4800(V32b).
V.32bis Override. Activates the Paradyne Point-to-Point Diagnostic 2400 bps modulation. Allows the modem to use a
non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 2400 bps.
NOTE: This configuration option must be the same in both the local and remote modems.
5-22
Default Configuration
Table 5-3
(1 of 3)
Dial Line Configuration Options — Multiport Mode l
October 1998
Options.
3920-A2-GH30-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

3921plusComsphere 3921plus