Powering Up the DSU

CAUTION:
The power cord contains a 3-wire grounding-type plug which has a
grounding pin. This is a safety feature. Grounding of the unit is vital to ensure
safe operation. Do not defeat the purpose of the grounding plug by modifying
it or by using an adapter. Prior to installation, use an outlet tester or voltmeter
to check the ac receptacle for earth ground. If the power source does not
provide a ground connection, consult an electrician to determine another
method of grounding the unit before proceeding with the installation.
"
Procedure
1. At the rear of the DSU, insert the small end of the power cable into the receptacle
labeled POWER.
POWER
LINE
CAUTION:
Only use the power transformer designed for the Model 3610 DSU. Using
other transformers may result in personal injury or damage to the equipment.
2. Connect the 3-prong plug at the other end of the cable to an ac outlet.

Power-Up Routine

When you apply power the first time, the DSU performs a power-up routine and:
H
Determines what hardware options are installed. This may include MUX to
represent TDM or MCMP.
H
Automatically runs a Device Test on the DSU and each installed hardware option.
All front panel lights flash on and off.
H
If a TDM or MCMP is installed, MUX appears as Pass or Fail on the LCD.
Refer to your User's Guide for power-up messages and steps for saving and changing
configuration options.
If a Fail message appears or an installed hardware option does not appear, refer to
Document No. 3610-A2-GB46 for DSU troubleshooting and Document No.
3610-A2-GB49 for DBM troubleshooting.
V.35
BACKUP CC/DC
PORT 5
PORT 3
PORT 6
PORT 4
9
EIA 232
PORT 2
495-14710