System Status Messages

System Health and Test Status Messages

9161-A2-GB20-00
These messages, listed in alphabetical order, appear in the messages area at the
bottom of the screens (see Table 5-3).
Table 5-3. System Status Messages
Message
What It Indicates
Already Active
The selected test is currently
running.
Command Complete
A system command (save,
clear, abort) completed
normally.
Connection Refused
User interface is in use. This
will only appear during
initiation of a Telnet session.
Please Wait
Command takes longer than
5 seconds.
User Interface Already
Access to the user interface
in Use
via Telnet is in use; access to
the interface is denied.
IP address and login of the
user currently accessing the
interface are also provided.
User Interface Idle
Previously active session is
now closed/ended, and
access via the COM port is
now available.
Session has ended due to
timeout.
The System and Test Status screen ( Path: main status system test status )
displays the following types of messages:
Health and Status – Displays Health and status information in priority order
(highest to lowest).
Self-Test Results – Displays the results of the power-up self-test
diagnostics.
Test Status – Indicates which tests are currently active.
November 1996
Maintenance and Troubleshooting
What To Do
1. Allow test to continue.
2. Stop the test.
No action needed.
Wait and try again.
Wait until message clears.
1. Wait and try again.
2. Contact IP address user
and request that they log
off.
Log onto the access unit.
Normal condition; no action
needed.
5-7