Paradyne 9161 User Manual page 47

Zhone 9161 mux: user guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

Maintenance and Troubleshooting
5-12
Table 5-5. Self-Test Results Messages (2 of 2)
Message
What It Indicates
Network T1 Fail
The NAM failed to internally
loop data on the network T1
circuit.
DSX-1 T1 Fail
The NAM failed to internally
loop data on the DSX-1 circuit.
Memory Fail
The unit failed memory
verification.
Failure xxxxxxxx
An internal failure occurred.
(xxxxxxxx represents an
eight-digit hexadecimal failure
code for use by service
personnel).
Passed
No problems were found
during power-up.
November 1996
What To Do
1. Reset the unit and try
again.
2. Call your service
representative for
assistance.
3. Return the unit to the
factory.
1. Reset the unit and try
again.
2. Call your service
representative for
assistance.
3. Return the unit to the
factory.
1. Reset the unit and try
again.
2. Call your service
representative for
assistance.
3. Return the unit to the
factory.
Record the failure code and
contact your service
representative.
No action needed; no
problems were found during
power-up or reset.
9161-A2-GB20-00