Paradyne 9161 User Manual page 40

Zhone 9161 mux: user guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

9161-A2-GB20-00
Table 5-1. ASCII Alarm Messages (4 of 4)
Message
mm/dd/yy hh:mm:ss –
A Secondary Clock Source
Failure has occurred.
mm/dd/yy hh:mm:ss –
Alarm Cleared for a
Secondary Source Failure.
mm/dd/yy hh:mm:ss –
A Primary Clock Source
Failure has occurred.
mm/dd/yy hh:mm:ss –
Alarm Cleared for a
Primary Source Failure.
November 1996
Maintenance and Troubleshooting
What It Indicates
What To Do
The secondary clock
1. If the secondary
source has failed. The
system is operating
from the internal clock.
2. Check the clock
Alarm condition no
No action needed.
longer exists.
The primary clock
1. If the primary
source has failed. The
system is operating
from the secondary
clock source.
2. Check the clock
Alarm condition no
No action needed.
longer exists.
Priority
15
clock was
derived from the
network, contact
the network
provider.
source. Contact
your service
representative.
16
clock was
derived from the
network, contact
the network
provider.
source. Contact
your service
representative.