Maintenance and Troubleshooting
5-2
Table 5-1. ASCII Alarm Messages (1 of 4)
Message
mm/dd/yy hh:mm:ss –
Alarm Indication Signal
(AIS) received at the
Network or DSX-1
Interface.
mm/dd/yy hh:mm:ss –
Alarm Cleared for Alarm
Indication Signal (AIS) at
the Network or DSX-1
Interface.
mm/dd/yy hh:mm:ss –
An APM Card Failure has
been detected for slot ss.
mm/dd/yy hh:mm:ss –
Alarm Cleared for an APM
Card Failure for slot ss .
mm/dd/yy hh:mm:ss –
Continuous Loss Of Signal
(LOS) condition detected at
the Network or DSX-1
Interface.
mm/dd/yy hh:mm:ss –
Alarm Cleared for Loss Of
Signal (LOS) condition at
the Network or DSX-1
Interface.
mm/dd/yy hh:mm:ss –
Continuous Out Of Frame
(OOF) detected at the
Network or DSX-1
Interface.
November 1996
What It Indicates
What To Do
An Alarm Indication
Check the status of
Signal condition is
the far-end unit. If
detected on the
necessary, contact
network or DSX-1
network provider for
interface.
Network interface.
Check the DTE
attached to the
DSX-1 interface.
Alarm condition no
No action needed.
longer exists.
An APM card failure is
1. Check that the
detected for the
identified slot.
2. Contact your
Alarm condition no
No action needed.
longer exists.
LOS condition
1. Check the cable
detected.
2. Contact network
Alarm condition no
No action needed.
longer exists.
An out-of-frame
1. Ensure that the
condition is detected
at the network or
DSX-1 interface.
2. Contact network
Priority
6 (Net)
7 (DSX-1)
11
APM card is
seated properly.
service
representative.
2 (Net)
to the
3 (DSX-1)
network/DSX-1
interface.
provider.
4 (Net)
line framing
5 (DSX-1)
format
configuration
option setting
matches the
setting of the
equipment
(DSX-1) or
network (Net).
provider.