Configuring Snmp Traps; Dialing Out Snmp Traps - Paradyne 7610 User Manual

Zhone 7610 network-accessory: user guide
Hide thumbs Also See for 7610:
Table of Contents

Advertisement

Configuring SNMP Traps

Dialing Out SNMP Traps

7610-A2-GB20-00
An SNMP trap can be automatically sent out the IMC or the Management port to
the SNMP manager when the DSU detects conditions set by the user. These
traps enable the SNMP manager to gauge the state of the network. Refer to
Standards Compliance for SNMP
supported by the DSU.
To configure the DSU for SNMP traps, use the SNMP Traps Options screen to:
Enable SNMP traps.
Set the number of SNMP managers that receive SNMP traps from the DSU.
Enter an IP address and network destination for each SNMP manager
specified.
Select the type of SNMP traps to be sent from the DSU.
To configure SNMP Traps, follow this menu selection sequence:
Main Menu
Configuration
SNMP & Communication
Refer to
SNMP Traps
Options, Table A-12.
Configure the SNMP traps before performing this procedure.
Procedure
1. Configure the phone directories to use when dialing out SNMP traps through
the Management port and a connected external device. Refer to the
Setup
section in Chapter 3.
2. Use the Alarms & Traps Options to enable the DSU's automatic call initiation
to a remote device with Alarm & Trap Dial-Out, Call Retry, and Alternate
Dial-Out Directory. Follow this menu selection sequence:
Main Menu
Configuration
Alarms & Traps
Refer to
Alarms & Traps
November 1996
Traps, Appendix D, for details of SNMP traps
Load Configuration From
SNMP Traps
Load Configuration From
Options, Table A-8.
Messages and Troubleshooting
Edit
Call
Edit
8-3