Wiring Options - Raytheon DIDS-400 Series Technical Manual

Digital information display system terminal
Table of Contents

Advertisement

DIDS-402 -2AM13
1-3.3
Wiring Options
Table 1-3 lists and defines the design options available for changing the
operating characteristics of the Display Terminal.
Table 1-3.
Wiring Options
Conversational Mode
Enquiry-Response or Polling
Broadcast Address
The Display Terminal recognizes
an address character other than
its own.
This option permits the
CPU to broadcast to two or more
Display Terminals simultaneously.
Frame Reset at End
The cursor is frame reset at the
of Transmit
end of a transmit sequence instead
of being advanced to the first
character position of the next line.
One-Step TransInit
Two options are available:
End-of-Transmis sion
Character
Advance Line After Receive
Nonblinking Cursor
1)
Depressing the END key inserts
an ETX code, then frame
resets the cursor and raises
the Request-to-Send line.
2)
Depre s sing the END key
inserts an ETX code and
then moves the cursor to the
fir st character position of
the line it is on and initiate s
automatic transmission to
the ETX.
An EOT character code (0000100)·
is substituted for the ETX
character code (0000011).
This
option is usually employed in
polling sites where EOT signifies
the end of transmission from the
site.
When an ETX character is decoded
in a received message, the cursor
is automatically advanced to the
first character position of the
next line.
A nonblinking cursor in the form of
a backward L
(J )
may be displayed
rather than the standard DIDS-400
blinking cur s or
(~
).
1-13