Brush Holder
1. Check the continuity across the brush holder and the holder
support with an ohmmeter.
2. If it conducts, replace the brush holder.
Armature Coil
1. Check the continuity across the commutator and armature coil
core with an ohmmeter.
2. If it conducts, replace the armature.
3. Check the continuity across the segments of the commutator
with an ohmmeter.
4. If it does not conduct, replace the armature.
Commutator –
Armature coil core
Resistance
Commutator segment
Field Coil
1. Check the continuity across the lead (1) and brush (2) with an
ohmmeter.
2. If it does not conduct, replace the yoke assembly.
3. Check the continuity across the brush (2) and yoke (3) with an
ohmmeter.
4. If it conducts, replace the yoke assembly.
Lead (1) – brush (2)
Resistance
Brush (2) – Yoke (3)
(1) Lead
(2) Brush
9-S35
ELECTRICAL SYSTEM
9Y1210365ELS0022US0
Infinity
0 Ω
9Y1210365ELS0023US0
0 Ω
Infinity
(3) Yoke
9Y1210365ELS0024US0