Chiller filter replacement

The chiller filter must be replaced every 6 months.
Parts required :
1 x New filter element - part number 1003282B00
5L container
Demineralized water
Caution: wear PPE (disposable rubber gloves, anti-static coverall, FFP3 respiratory protection, anti-static
safety shoes) .
1.
Switch off the printer (see section "Shutting printer down" on page 69).
2.
Switch off the 2 UPS (see "E. Control/supply cabinet" on page 28).
3.
Lock out and tag out the printer: position the main switch from the supply cabinet to position "O", then put a lock with a
tag out label on the switch. This will disconnect and isolate the printer from energy during the maintenance.
4.
Open the right door of the control/supply cabinet.
5.
The filter is located on the right corner. Close the input and output valves (A and B).
6.
Unscrew the transparent filter cover and remove it by pulling downwards in order to reveal the inserted filter element.
7.
Replace the old filter element with the new one.
8.
Screw the transparent filter cover.
9.
Open the input and output valves (A and B).
10. Re-start the printer (see section page 33).
3D SYSTEMS, INC.
92