10. Remove the side panels of the chiller.
11. Blow the dirt out of the block by using compressed air and vacuum cleaner. It
may be necessary to use a solvent in order to remove any oil residue. Should
the accumulated dirt be excessive, the fan can be removed to assist the
cleaning. Clean the fan blades. Remove all dirt deposits from the fan housing.
Do not damage components inside the chiller (evaporator,
compressor, heat exchanger . . .) .
12. Put back the side panels of the chiller.
13. Put the chiller back to the control/supply cabinet and secure it by tightening the screws removed on step 9.
Make sure to install the chiller without damaging the air ducting hose .
14. Secure the chiller to the air ducting hose by tightening the screws removed on the step 7.
15. Re-plug the cables into the chiller that were removed on the step 6.
16. Gather the control/supply cabinet close to the main cabinet.
17. Re-start the printer (see section "Powering up the printer" on page 33).