7-1-24 Dual User Monitor [d050]

Use this function to display two set monitor items by switching between them with the Jog dial.
In b160 and b161, set the parameter numbers whose data you want to monitor.
(Example) To monitor the d001 data, set b160 or b161 to 001.
Parameter
No.
d050
Dual User Monitor
b160
User Monitor Selection 1
b161
User Monitor Selection 2
Precautions for Correct Use
Even if you select d001 or d007 in b160/b161 and then set the d001/d007 Data Setting Selec-
tion (b163) to 01 (Enabled), you cannot switch the data from d050 via key operation.

7-1-25 Inverter Mode Monitor [d060]

Use this function to display the current inverter mode.
The Inverter mode setting can be changed by Heavy load/Light Load Selection (b049) and Inverter
Mode Selection (b171). For details on each mode, refer to 5-2-2 Heavy load/Light Load Selection on
page 5-11 and 6-8 PM Motor Mode on page 6-54.
Parameter
No.
d060
Inverter Mode Monitor
Related functions
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Function name
Displays two monitor items set in b160 and
b161.
001 to 030
(Corresponding to d001 to d030)
Enter
JOG
Function name
I-C:
I-V:
H-I:
P:
b049, b171
Data
Monitor item 1 data
selected in b160
JOG
Monitor item 2 data
selected in b161
Data
IM motor heavy load mode
IM motor light load
IM motor high-frequency mode
PM motor mode
7 Other Functions
Default
Unit
data
001
002
Default
Unit
data
7 - 13
7