Parameter
Function name
No.
Window Comparator
b060
O Upper Limit Level
Window Comparator
b061
O Lower Limit Level
Window Comparator
b062
O Hysteresis Width
Window Comparator
b063
OI Upper Limit Level
Window Comparator
b064
OI Lower Limit Level
Window Comparator
b065
OI Hysteresis Width
Analog Operation
b070
Level at O
Disconnection
Analog Operation
b071
Level at OI Discon-
nection
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
Monitor or data range
Set an upper limit level.
Setting range: 0. to 100.
Lower limit: Lower limit level + Hysteresis
width 2
Set a lower limit level.
Setting range: 0. to 100.
Upper limit: Upper limit level − Hysteresis
width 2
Set a hysteresis width for the upper and
lower limit levels.
Setting range: 0. to 10.
Upper limit: (Upper limit level − Lower
limit level) / 2
Set an upper limit level.
Setting range: 0. to 100.
Lower limit: Lower limit level + Hysteresis
width 2
Set a lower limit level.
Setting range: 0. to 100.
Upper limit: Upper limit level − Hysteresis
width 2
Set a hysteresis width for the upper and
lower limit levels.
Setting range: 0. to 10.
Upper limit: (Upper limit level − Lower
limit level) / 2
0. to 100.
255: no (Disabled)
0. to 100.
255: no (Disabled)
4 Parameter List
Changes
Default
Set
during
data
data
RUN
100.
Enabled
0.
Enabled
0.
Enabled
100.
Enabled
0.
Enabled
0.
Enabled
no
Enabled
no
Enabled
Unit
Page
%
%
%
%
P. 7-90
4
%
%
%
%
4 - 19