Omron MX2 Series User Manual page 506

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

8 Communications Functions
Modbus
Register
register
No.
spec. No
1316 hex
1315 hex
1317 hex
1316 hex
1318 hex
1317 hex
1319 hex
1318 hex
131A hex
1319 hex
131B hex
131A hex
131C hex
131B hex
131D hex
131C hex
131E hex
131D hex
131F hex
131E hex
8 - 62
Parameter
Function name
No.
1st Overload Limit
b021
Selection
1st Overload Limit
b022
Level
1st Overload Limit
b023
Parameter
1st Overload Limit
b024
Selection 2
1st Overload Limit
b025
Level 2
1st Overload Limit
b026
Parameter 2
Overcurrent
Suppression
b027
Selection
Frequency Pull-in
b028
Restart Level
Frequency Pull-in
b029
Restart Parameter
Starting Frequency
Selection at Fre-
b030
quency Pull-in
Restart
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
R/W
Monitor or setting data
00:
Disabled
01:
Enabled during
acceleration and
constant speed
02:
Enabled during
constant speed
R/W
03:
Enabled during
acceleration and
constant speed
(Accelerated
during regenera-
tion)
R/W
200 to 2000 (1500)
R/W
1 to 30000
00:
Disabled
01:
Enabled during
acceleration and
constant speed
02:
Enabled during
constant speed
R/W
03:
Enabled during
acceleration and
constant speed
(Accelerated
during regenera-
tion)
R/W
200 to 2000 (1500)
R/W
1 to 30000
00:
Disabled
01:
Enabled
R/W
02:
Enabled (at reduced
voltage startup)
R/W
200 to 2000 (1500)
R/W
1 to 30000
00:
Frequency at
interruption
01:
Maximum fre-
quency
R/W
02:
Set frequency
(Frequency refer-
ence)
Data
Page
resolution
0.1 [%]
0.1 [s]
P. 7-78
0.1 [%]
0.1 [s]
P. 7-81
0.1 [%]
0.1 [s]
P. 5-44
P. 7-62

Advertisement

Table of Contents
loading

Table of Contents